Service time: Monday to Friday 9:00-18:00
PLC-RPT-230AC/21HC/SO46/HI - PLC-RPT-230AC/21HC/SO46/HI 1079404 PHOENIX CONTACT PLC-INTERFACE consisting of PLC-BSC.../21HC/SO46/HI basic..
In Stock Hot Product

PLC-RPT-230AC/21HC/SO46/HI

PLC-RPT-230AC/21HC/SO46/HI 1079404 PHOENIX CONTACT PLC-INTERFACE consisting of PLC-BSC.../21HC/SO46/HI basic..

$0.00USD
4027 in stock
Key Specifications
GTIN:4055626798677
Orderkey:1079404
(General):Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626798677
Orderkey1079404
(General)Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
(Drawings)
(Coil side)6 A (at 250 V, AC15)
Catalog pagePage 393 (C-5-2019)
Depth (Note)94 mm
Packing unit1
Width (Note)14 mm
(Dimensions)IP20 (Relay base)
Height (Note)80 mm
(Contact side)2x 0.5 mm² ... 1 mm² (TWIN ferrule)
ETIM 5.0 (eCl@ss)EC001437
ETIM 6.0 (eCl@ss)EC001437
(Connection data)2x 0.5 mm² ... 1 mm² (TWIN ferrule)
(Connection data 2)IP20 (Relay base)
Custom tariff number85364900
Insulation (General)Basic insulation
Designation (General)Air clearances and creepage distances between the power circuits
Contact type (Coil side)1 PDT
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Coil side)AgNi
eCl@ss 8.0 (Classifications)27371601
eCl@ss 9.0 (Classifications)27371601
Degree of pollution (General)2
Maximum altitude (Dimensions)≤ 2000 m
Rated surge voltage (General)4 kV
Connection name (Contact side)Coil side
Overvoltage category (General)III
Switching capacity (Coil side)2 A (at 24 V, DC13)
Standards/regulations (General)IEC 60664
Stripping length (Contact side)8 mm
Connection method (Contact side)Push-in connection
Coil voltage (Ambient conditions)60 V DC
Connection name (Connection data)Contact side
Degree of protection (Dimensions)RT II (Relay)
Input circuit (Ambient conditions)RC element with threshold value switch
Maximum inrush current (Coil side)30 A (300 ms)
Min. switching current (Coil side)10 mA (at 12 V)
Operating mode (Connection data 2)100% operating factor
Stripping length (Connection data)8 mm
Type of switch contact (Coil side)Single contact
Utilization restriction (Drawings)EMC: class A product, see manufacturer's declaration in the download area
Connection method (Connection data)Push-in connection
Maximum switching voltage (Coil side)250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage (Coil side)12 V (at 10 mA)
Mounting position (Connection data 2)any
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Limiting continuous current (Coil side)10 A
Protective circuit (Ambient conditions)Bridge rectifier
Degree of protection (Connection data 2)RT II (Relay)
Switch-on threshold (Ambient conditions)190 V AC
Assembly instructions (Connection data 2)In rows with zero spacing
DiagramElectrical service life (Drawings)
Switch-off threshold (Ambient conditions)170 V AC
Typical release time (Ambient conditions)8 ms
Conductor cross section AWG (Contact side)26 ... 14
Typical response time (Ambient conditions)10 ms
Mechanical service life (Connection data 2)3x 107cycles
Ambient temperature (operation) (Dimensions)-40 °C ... 50 °C
Conductor cross section solid (Contact side)0.14 mm² ... 2.5 mm²
Conductor cross section AWG (Connection data)26 ... 14
Nominal input voltage UN (Ambient conditions)230 V AC
Operating voltage display (Ambient conditions)Yellow LED
Conductor cross section flexible (Contact side)0.14 mm² ... 2.5 mm²
Conductor cross section solid (Connection data)0.14 mm² ... 2.5 mm²
DiagramService life reduction factor (Drawings)
Flammability rating according to UL 94 (General)V0
Typical input current at UN (Ambient conditions)16 mA
Interrupting rating (ohmic load) max. (Coil side)240 W (at 24 V DC)
Conductor cross section flexible (Connection data)0.14 mm² ... 2.5 mm²
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Interrupting rating (ohmic load) max. bridged (Coil side)144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Degree of protection at installation location (Dimensions)IP54
Power dissipation for nominal condition (Ambient conditions)1.04 W
Test voltage relay winding/relay contact (Connection data 2)4 kV AC (50 Hz, 1 min.)

Product Description

PLC-INTERFACE, consisting of PLC-BSC.../21HC/SO46/HI base terminal block with push-in connection and plug-in miniature relays for high constant current, 1 switch, nominal input voltage of 230 V AC, wi
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

DiagramElectrical service life

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top