Key Specifications
:Surge protection; Freewheeling diode
EMC:B
Color:gray (RAL 7042)
Depth:94 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Surge protection; Freewheeling diode
EMCB
Colorgray (RAL 7042)
Depth94 mm
Width14 mm
Height80 mm
HumidityA
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationB/C
InsulationSafe isolation, reinforced insulation
ApplicationHigh continuous currents
CertificateCE-compliant
TemperatureD
Product typeRelay Module
Assembly notein rows with zero spacing
Mounting typeDIN rail mounting
IdentificationISA-S71.04. G3 Harsh Group
Operating mode100% operating factor
Product familyPLC-INTERFACE
Article revision08
Contact materialAgNi
Drive (polarity)polarized
Pollution degree3
Stripping length10 mm
Connection methodPush-in connection
Mounting positionany
Drive and functionmonostable
Protective circuitReverse polarity protection; Polarity protection diode
Switching capacity2 A (at 24 V, DC13)
Input voltage range10.3 V DC ... 16.8 V DC (20 °C)
Rated surge voltage6 kV
Overvoltage categoryIII
Typical release time10 ms
Low Voltage DirectiveConformance with Low Voltage Directive
Standards/regulationsIEC 60947-5-1
Typical response time8 ms
Contact switching type1 changeover contact
Maximum inrush current30 A (300 ms)
Min. switching current10 mA (12 V)
Type of switch contactSingle contact
Mechanical service life3x 107cycles
Nominal input voltage UN12 V DC
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage12 V (10 mA)
Operating voltage displayYellow LED
Conductor cross section AWG26 ... 14
Limiting continuous current10 A
Typical input current at UN33 mA
Date of last data management03.07.2024
Degree of protection (Relay)RT II (Relay)
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Electromagnetic compatibilityConformance with EMC directive
Ambient temperature (operation)-40 °C ... 60 °C
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Degree of protection (Relay base)IP20 (Relay base)
Interrupting rating (ohmic load) max.240 W (at 24 V DC)
Flammability rating according to UL 94V0 (Housing)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Interrupting rating (ohmic load) max. bridged144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Maximum power dissipation for nominal condition0.4 W
Nominal voltage (plugged-in electromechanical relay)12 V DC

Product Description

PLC-INTERFACE for high constant currents, consisting of PLC-BPT.../21 HC base terminal block with push-in connection and plug-in miniature relay, for mounting on NS 35/7.5 rail, constant current limit
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top