| Parameter | Value |
|---|---|
| GTIN | 4055626363707 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2909533 |
| (General) | 2x 0.5 mm² ... 1 mm² () |
| (Coil side) | 6 A (at 250 V, AC15) |
| Catalog page | Page 459 (C-5-2017) |
| Depth (Note) | 94 mm |
| Packing unit | 10 pc |
| Width (Note) | 14 mm |
| (Dimensions) | -40 °C ... 60 °C (ATEX / IECEx) |
| Height (Note) | 80 mm |
| (Contact side) | IP20 (Relay base) |
| Country of origin | DE (Germany) |
| ATEX (Contact side) | II 3G Ex ec nC IIC T4 Gc |
| Custom tariff number | 85364900 |
| IECEx (Contact side) | Ex ec nC IIC T4 Gc |
| (Ambient conditions) | 110 V DC |
| Minimum order quantity | 10 pc |
| UL, USA (Contact side) | Class I, Zone 2, AEx nA nC IIC T6 |
| Contact type (Coil side) | 1 PDT |
| Connection name (General) | Coil side |
| UL, Canada (Contact side) | Class I, Zone 2, Ex nA nC IIC Gc T6 X |
| Stripping length (General) | 8 mm |
| Connection method (General) | Push-in connection |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Coil side) | AgNi |
| (Connection data input side) | 2x 0.5 mm² ... 1 mm² () |
| Operating mode (Contact side) | 100% operating factor |
| UL, USA/Canada (Contact side) | Class I, Div. 2, Groups A, B, C, D |
| (Connection data output side) | EN 60079-0, -7, -15 |
| Switching capacity (Coil side) | 2 A (at 24 V, DC13) |
| Net weight (SAP) (Contact side) | 66.48 g |
| IECEx certificate (Contact side) | IECEx IBE 16.0029X |
| Mounting position (Contact side) | any |
| ATEX (Connection data output side) | II 3G Ex ec nC IIC T4 Gc |
| Maximum inrush current (Coil side) | 30 A (300 ms) |
| Min. switching current (Coil side) | 10 mA (at 12 V) |
| Type of switch contact (Coil side) | Single contact |
| Degree of protection (Contact side) | RT II (Relay) |
| IECEx (Connection data output side) | Ex ec nC IIC T4 Gc |
| Assembly instructions (Contact side) | In rows with zero spacing |
| Weight per Piece (excluding packing) | 66.480 g |
| Conductor cross section AWG (General) | 26 ... 14 |
| Maximum switching voltage (Coil side) | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Minimum switching voltage (Coil side) | 12 V (at 10 mA) |
| UL, USA (Connection data output side) | Class I, Zone 2, AEx nA nC IIC T6 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Mechanical service life (Contact side) | 3x 107cycles |
| Conductor cross section solid (General) | 0.14 mm² ... 2.5 mm² |
| Limiting continuous current (Coil side) | 10 A |
| Protective circuit (Ambient conditions) | Bridge rectifier Bridge rectifier |
| Insulation (Connection data output side) | Safe isolation, reinforced insulation |
| UL, Canada (Connection data output side) | Class I, Zone 2, Ex nA nC IIC Gc T6 X |
| Conformance (Connection data output side) | CE-compliant |
| Designation (Connection data output side) | Standards/regulations |
| Typical release time (Ambient conditions) | 10 ms |
| Conductor cross section flexible (General) | 0.14 mm² ... 2.5 mm² |
| Typical response time (Ambient conditions) | 7 ms |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 60 °C (UL) |
| Connection name (Connection data input side) | Contact side |
| UL, USA/Canada (Connection data output side) | Class I, Div. 2, Groups A, B, C, D |
| Nominal input voltage UN (Ambient conditions) | 120 V AC |
| Stripping length (Connection data input side) | 8 mm |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Connection method (Connection data input side) | Push-in connection |
| EU-type examination certificate (Contact side) | IBExU16ATEXB015 X |
| Operating voltage display (Ambient conditions) | Yellow LED |
| Typical input current at UN (Ambient conditions) | 4.5 mA |
| Degree of pollution (Connection data output side) | 2 |
| Interrupting rating (ohmic load) max. (Coil side) | 240 W (at 24 V DC) |
| Rated surge voltage (Connection data output side) | 6 kV |
| Overvoltage category (Connection data output side) | III |
| Standards/regulations (Connection data output side) | IEC 60664 |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Rated insulation voltage (Connection data output side) | 250 V AC |
| Test voltage relay winding/relay contact (Contact side) | 4 kV AC (50 Hz, 1 min.) |
| Conductor cross section AWG (Connection data input side) | 26 ... 14 |
| Interrupting rating (ohmic load) max. bridged (Coil side) | 144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) |
| Conductor cross section solid (Connection data input side) | 0.14 mm² ... 2.5 mm² |
| Power dissipation for nominal condition (Ambient conditions) | 0.54 W |
| Conductor cross section flexible (Connection data input side) | 0.14 mm² ... 2.5 mm² |
| Flammability rating according to UL 94 (Connection data output side) | V0 |
Technical specifications and performance data
Installation and operation guide