Service time: Monday to Friday 9:00-18:00
PLC-OSC-12DC/300DC/ 1 - PLC-OSC- 12DC/300DC/ 1 2980665 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with screw conne..
In Stock Hot Product

PLC-OSC-12DC/300DC/ 1

PLC-OSC- 12DC/300DC/ 1 2980665 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with screw conne..

$0.00USD
4437 in stock
Key Specifications
:Surge protection
Depth:86 mm
Width:6.2 mm
Height:80 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Surge protection
Depth86 mm
Width6.2 mm
Height80 mm
DesignationOutput data
Screw threadM3
Operating mode100% operating factor
Connection nameInput side
Pollution degree2
Stripping length8 mm
Connection methodScrew connection
Mounting positionany
Type of protectionProtection against polarity reversal
Output voltage range12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Overvoltage categoryIII
Assembly instructionsIn rows with zero spacing
Standards/regulationsIEC 60664
Typical response time0.3 ms
Typical turn-off time0.8 ms
Transmission frequency50 Hz
Nominal input voltage UN12 V DC
Rated insulation voltage300 V
Operating voltage displayYellow LED
Conductor cross section AWG26 ... 14
Limiting continuous current1 A (see derating curve)
Typical input current at UN6 mA
Protective circuit/componentPolarity protection diode
Conductor cross section solid0.14 mm² ... 2.5 mm²
Rated surge voltage/insulation4 kV / basic insulation
Ambient temperature (operation)-25 °C ... 60 °C
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Flammability rating according to UL 94V0
Input voltage range in reference to UN0.8 ... 1.2
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage drop at max. limiting continuous current< 500 mV
Switching threshold "0" signal in reference to UN≤ 0.4
Switching threshold "1" signal in reference to UN≥ 0.8

Product Description

PLC INTERFACE, integrated solid-state relay, screw connection, for installation on NS 35/7.5 symmetrical rail, input: 12 V DC, output: 12-300 V DC/1 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top