| Parameter | Value |
|---|---|
| (General) | IEC 62103 |
| Depth (Note) | 86 mm |
| Width (Note) | 6.2 mm |
| (Input data) | Varistor |
| Height (Note) | 80 mm |
| UNSPSC 11 (ETIM) | 39121542 |
| ETIM 2.0 (eCl@ss) | EC001504 |
| ETIM 3.0 (eCl@ss) | EC001504 |
| ETIM 4.0 (eCl@ss) | EC000196 |
| ETIM 5.0 (eCl@ss) | EC001504 |
| UNSPSC 13.2 (ETIM) | 39121542 |
| UNSPSC 6.01 (ETIM) | 30211916 |
| UNSPSC 12.01 (ETIM) | 39121542 |
| UNSPSC 7.0901 (ETIM) | 39121542 |
| (Ambient conditions) | Varistor |
| Designation (General) | Standards/regulations |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
| Designation (Input data) | Output data |
| Connection name (Output data) | Input side |
| Degree of pollution (General) | 2 |
| Overvoltage category (General) | III |
| Stripping length (Output data) | 8 mm |
| (Connection data, output side) | IEC 62103 |
| Connection method (Output data) | Push-in connection |
| Standards/regulations (General) | IEC 60664 |
| Type of protection (Input data) | Reverse polarity protection |
| Output voltage range (Input data) | 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Rated insulation voltage (General) | 300 V |
| eCl@ss 4.0 (Standards and Regulations) | 27371102 |
| eCl@ss 4.1 (Standards and Regulations) | 27371102 |
| eCl@ss 5.0 (Standards and Regulations) | 27371001 |
| eCl@ss 5.1 (Standards and Regulations) | 27371001 |
| eCl@ss 6.0 (Standards and Regulations) | 27371001 |
| eCl@ss 7.0 (Standards and Regulations) | 27371001 |
| eCl@ss 8.0 (Standards and Regulations) | 27371604 |
| eCl@ss 9.0 (Standards and Regulations) | 27371604 |
| Type of protection (Ambient conditions) | Reverse polarity protection |
| Input voltage range (Ambient conditions) | 48 V DC ... 60 V DC |
| Limiting continuous current (Input data) | 1 A (see derating curve) |
| Rated surge voltage/insulation (General) | 4 kV / basic insulation |
| Conductor cross section AWG (Output data) | 26 ... 14 |
| Protective circuit/component (Input data) | Polarity protection diode |
| Connection in acc. with standard (General) | CUL |
| Designation (Connection data, output side) | Standards/regulations |
| Typical response time (Ambient conditions) | 0.3 ms |
| Typical turn-off time (Ambient conditions) | 0.7 ms |
| Conductor cross section solid (Output data) | 0.14 mm² ... 2.5 mm² |
| Transmission frequency (Ambient conditions) | 50 Hz |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C |
| Connection name (Connection data, input side) | Output side |
| Nominal input voltage UN (Ambient conditions) | 60 V DC |
| Operating mode (Connection data, output side) | 100% operating factor |
| Conductor cross section flexible (Output data) | 0.14 mm² ... 2.5 mm² |
| Operating voltage display (Ambient conditions) | Yellow LED |
| Stripping length (Connection data, input side) | 8 mm |
| Connection method (Connection data, input side) | Push-in connection |
| Flammability rating according to UL 94 (General) | V0 |
| Mounting position (Connection data, output side) | any |
| Typical input current at UN (Ambient conditions) | 5 mA |
| Protective circuit/component (Ambient conditions) | Polarity protection diode |
| Degree of pollution (Connection data, output side) | 2 |
| Overvoltage category (Connection data, output side) | III |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Assembly instructions (Connection data, output side) | In rows with zero spacing |
| Standards/regulations (Connection data, output side) | IEC 60664 |
| Rated insulation voltage (Connection data, output side) | 300 V |
| Conductor cross section AWG (Connection data, input side) | 26 ... 14 |
| Conductor cross section solid (Connection data, input side) | 0.14 mm² ... 2.5 mm² |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.2 |
| Rated surge voltage/insulation (Connection data, output side) | 4 kV / basic insulation |
| Voltage drop at max. limiting continuous current (Input data) | < 500 mV |
| Conductor cross section flexible (Connection data, input side) | 0.14 mm² ... 2.5 mm² |
| Flammability rating according to UL 94 (Connection data, output side) | V0 |
| Switching threshold "0" signal in reference to UN (Ambient conditions) | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN (Ambient conditions) | ≥ 0.8 |