Key Specifications
(General):IEC 62103
Depth (Note):86 mm
Width (Note):6.2 mm
(Input data):Surge protection
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
(General)IEC 62103
Depth (Note)86 mm
Width (Note)6.2 mm
(Input data)Surge protection
Height (Note)80 mm
UNSPSC 11 (ETIM)39121542
ETIM 4.0 (eCl@ss)EC000196
ETIM 5.0 (eCl@ss)EC001504
UNSPSC 13.2 (ETIM)39121542
UNSPSC 6.01 (ETIM)30211916
UNSPSC 12.01 (ETIM)39121542
Fan out (Input data)1
UNSPSC 7.0901 (ETIM)39121542
(Ambient conditions)Surge protection
Designation (General)Air clearances and creepage distances between the power circuits
Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Designation (Input data)Output data
Output circuit (Input data)3-conductor, ground-referenced
Connection name (Output data)Input side
Degree of pollution (General)2
Overvoltage category (General)III
Stripping length (Output data)8 mm
(Connection data, output side)IEC 62103
Connection method (Output data)Push-in connection
Standards/regulations (General)IEC 60664
Type of protection (Input data)Reverse polarity protection
Degree of protection (Dimensions)IP20
Rated insulation voltage (General)250 V DC
Output nominal voltage (Input data)5 V DC -10 % ... +20 %
Surge voltage protection (Input data)> 8 V
eCl@ss 4.0 (Standards and Regulations)27371001
eCl@ss 4.1 (Standards and Regulations)27371001
eCl@ss 5.0 (Standards and Regulations)27371001
eCl@ss 5.1 (Standards and Regulations)27371001
eCl@ss 6.0 (Standards and Regulations)27371001
eCl@ss 7.0 (Standards and Regulations)27371001
eCl@ss 8.0 (Standards and Regulations)27371604
eCl@ss 9.0 (Standards and Regulations)27371604
Type of protection (Ambient conditions)Reverse polarity protection
Limiting continuous current (Input data)A TTL load (Fan out = 1)/50 mA for switching mode
Rated surge voltage/insulation (General)4 kV / basic insulation
Conductor cross section AWG (Output data)26 ... 14
Protective circuit/component (Input data)Parallel polarity protection diode
Connection in acc. with standard (General)CUL
Designation (Connection data, output side)Air clearances and creepage distances between the power circuits
Typical response time (Ambient conditions)35 µs
Typical turn-off time (Ambient conditions)35 µs
Conductor cross section solid (Output data)0.14 mm² ... 2.5 mm²
Transmission frequency (Ambient conditions)1 kHz
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Connection name (Connection data, input side)Output side
Nominal input voltage UN (Ambient conditions)24 V DC
Operating mode (Connection data, output side)100% operating factor
Surge voltage protection (Ambient conditions)> 33 V
Conductor cross section flexible (Output data)0.14 mm² ... 2.5 mm²
Operating voltage display (Ambient conditions)Yellow LED
Stripping length (Connection data, input side)8 mm
Connection method (Connection data, input side)Push-in connection
Flammability rating according to UL 94 (General)V0
Mounting position (Connection data, output side)any
Typical input current at UN (Ambient conditions)3.4 mA
Protective circuit/component (Ambient conditions)Parallel polarity protection diode
Degree of pollution (Connection data, output side)2
Overvoltage category (Connection data, output side)III
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Assembly instructions (Connection data, output side)In rows with zero spacing
Standards/regulations (Connection data, output side)IEC 60664
Rated insulation voltage (Connection data, output side)250 V DC
Test voltage input/output (Connection data, output side)2.5 kVrms(50 Hz, 1 min.)
Conductor cross section AWG (Connection data, input side)26 ... 14
Conductor cross section solid (Connection data, input side)0.14 mm² ... 2.5 mm²
Input voltage range in reference to UN (Ambient conditions)0.8 ... 1.2
Rated surge voltage/insulation (Connection data, output side)4 kV / basic insulation
Voltage drop at max. limiting continuous current (Input data)< 80 mV
Conductor cross section flexible (Connection data, input side)0.14 mm² ... 2.5 mm²
Flammability rating according to UL 94 (Connection data, output side)V0
Switching threshold "0" signal in reference to UN (Ambient conditions)< 0.4
Switching threshold "1" signal in reference to UN (Ambient conditions)> 0.8

Product Description

PLC-INTERFACE for TTL signal, consisting of PLC-O.../TTL base terminal block with push-in connection and integrated solid-state relay, for installation on NS 35/7.5 rail, 1 closing contact, input: 24
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top