Service time: Monday to Friday 9:00-18:00
PLC-OPT-12DC/300DC/1 - PLC-OPT- 12DC/300DC/1 2900382 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with Push-in conn..
In Stock Hot Product

PLC-OPT-12DC/300DC/1

PLC-OPT- 12DC/300DC/1 2900382 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with Push-in conn..

$0.00USD
3053 in stock
Key Specifications
(General):IEC 62103
Depth (Note):86 mm
Width (Note):6.2 mm
(Input data):Varistor
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
(General)IEC 62103
Depth (Note)86 mm
Width (Note)6.2 mm
(Input data)Varistor
Height (Note)80 mm
UNSPSC 11 (ETIM)39121542
ETIM 2.0 (eCl@ss)EC001504
ETIM 3.0 (eCl@ss)EC001504
ETIM 4.0 (eCl@ss)EC000196
ETIM 5.0 (eCl@ss)EC001504
UNSPSC 13.2 (ETIM)39121542
UNSPSC 6.01 (ETIM)30211916
UNSPSC 12.01 (ETIM)39121542
UNSPSC 7.0901 (ETIM)39121542
(Ambient conditions)Varistor
Designation (General)Standards/regulations
Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Designation (Input data)Output data
Connection name (Output data)Input side
Degree of pollution (General)2
Overvoltage category (General)III
Stripping length (Output data)8 mm
(Connection data, output side)IEC 62103
Connection method (Output data)Push-in connection
Standards/regulations (General)IEC 60664
Type of protection (Input data)Reverse polarity protection
Output voltage range (Input data)12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Rated insulation voltage (General)300 V
eCl@ss 4.0 (Standards and Regulations)27371102
eCl@ss 4.1 (Standards and Regulations)27371102
eCl@ss 5.0 (Standards and Regulations)27371001
eCl@ss 5.1 (Standards and Regulations)27371001
eCl@ss 6.0 (Standards and Regulations)27371001
eCl@ss 7.0 (Standards and Regulations)27371001
eCl@ss 8.0 (Standards and Regulations)27371604
eCl@ss 9.0 (Standards and Regulations)27371604
Type of protection (Ambient conditions)Reverse polarity protection
Input voltage range (Ambient conditions)9.6 V DC ... 14.4 V DC
Limiting continuous current (Input data)1 A (see derating curve)
Rated surge voltage/insulation (General)4 kV / basic insulation
Conductor cross section AWG (Output data)26 ... 14
Protective circuit/component (Input data)Polarity protection diode
Connection in acc. with standard (General)CUL
Designation (Connection data, output side)Standards/regulations
Typical response time (Ambient conditions)0.3 ms
Typical turn-off time (Ambient conditions)0.8 ms
Conductor cross section solid (Output data)0.14 mm² ... 2.5 mm²
Transmission frequency (Ambient conditions)50 Hz
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Connection name (Connection data, input side)Output side
Nominal input voltage UN (Ambient conditions)12 V DC
Operating mode (Connection data, output side)100% operating factor
Conductor cross section flexible (Output data)0.14 mm² ... 2.5 mm²
Operating voltage display (Ambient conditions)Yellow LED
Stripping length (Connection data, input side)8 mm
Connection method (Connection data, input side)Push-in connection
Flammability rating according to UL 94 (General)V0
Mounting position (Connection data, output side)any
Typical input current at UN (Ambient conditions)6 mA
Protective circuit/component (Ambient conditions)Polarity protection diode
Degree of pollution (Connection data, output side)2
Overvoltage category (Connection data, output side)III
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Assembly instructions (Connection data, output side)In rows with zero spacing
Standards/regulations (Connection data, output side)IEC 60664
Rated insulation voltage (Connection data, output side)300 V
Conductor cross section AWG (Connection data, input side)26 ... 14
Conductor cross section solid (Connection data, input side)0.14 mm² ... 2.5 mm²
Input voltage range in reference to UN (Ambient conditions)0.8 ... 1.2
Rated surge voltage/insulation (Connection data, output side)4 kV / basic insulation
Voltage drop at max. limiting continuous current (Input data)< 500 mV
Conductor cross section flexible (Connection data, input side)0.14 mm² ... 2.5 mm²
Flammability rating according to UL 94 (Connection data, output side)V0
Switching threshold "0" signal in reference to UN (Ambient conditions)≤ 0.4
Switching threshold "1" signal in reference to UN (Ambient conditions)≥ 0.8

Product Description

INTERFACE PLC, integrated solid-state relay, with push-in connection, for symmetrical rail mounting NS 35/7.5, input: 12 V DC, output: 12-300 V DC/1 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top