Key Specifications
:The nominal voltage of the plug-on electromechanical relay or solid-state relay (see necessary accessories) deviates from the nominal input voltage of the base with integrated upstream circuit
EMC:B
Color:gray (RAL 7042)
Depth:94 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
The nominal voltage of the plug-on electromechanical relay or solid-state relay (see necessary accessories) deviates from the nominal input voltage of the base with integrated upstream circuit
EMCB
Colorgray (RAL 7042)
Depth94 mm
Width6.2 mm
Height80 mm
EMC noteEMC: class A product, see manufacturer's declaration in the download area
HumidityA
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationB/C
ApplicationOutput function
CertificateCE-compliant
TemperatureD
Product typeRelay socket
Assembly notein rows with zero spacing
Mounting typeDIN rail mounting
IdentificationISA-S71.04. G3 Harsh Group
Operating mode100% operating factor
Output circuit2-conductor, floating
Product familyPLC-INTERFACE
Leakage current≤ 1 mA
Max. load value4.5 A2s (tp = 10 ms, at 25 °C)
Article revision06
Stripping length10 mm
Connection methodPush-in connection
Mounting positionany
Protective circuitBridge rectifier
Typical release time30 ms
Compatible componentsMiniature relay, REL-MR-24DC/21, REL-MR-24DC/21AU; miniature optocoupler, OPT-24DC/24DC/2, OPT-24DC/48DC/100, OPT-24DC/230AC/1
Low Voltage DirectiveConformance with Low Voltage Directive
Typical response time5 ms
Nominal input voltage UN24 V AC/DC
Maximum switching voltage33 V DC
Minimum switching voltage3 V DC
Operating voltage displayYellow LED
Conductor cross section AWG26 ... 14
Limiting continuous current3 A (see derating curve)
Typical input current at UN15.6 mA (50 Hz)
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Electromagnetic compatibilityConformance with EMC directive
Ambient temperature (operation)-20 °C ... 60 °C
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Voltage range with reference to US0.8 ... 1.2
Flammability rating according to UL 94V0 (Housing)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Rated control circuit supply voltage US24 V AC/DC
Voltage drop at max. limiting continuous current≤ 150 mV

Product Description

6.2 mm PLC base terminal block for output functions with push-in connection, without relay or solid-state relay equipment, for mounting on NS 35/7.5 rail, with load return line (BB) connection, 1 clos
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top