| Parameter | Value |
|---|---|
| GTIN | 4017918911799 |
| Orderkey | 2835901 |
| (General) | II 3 G Ex nA II T4 X |
| Catalog page | Page 467 (IF-2009) |
| Packing unit | 10 pc |
| ATEX (General) | II (1) G [Ex ia] IIC |
| Country of origin | DE (Germany) |
| Custom tariff number | 85369010 |
| (Ambient conditions) | II 3 G Ex nA II T4 X |
| Conformance (General) | CE-compliant |
| UL, USA/Canada (General) | Class I, Div. 2, Groups A, B, C, D |
| ATEX (Ambient conditions) | II (1) G [Ex ia] IIC |
| Color (Ambient conditions) | gray |
| Depth (Key Commercial Data) | 86.5 mm |
| Width (Key Commercial Data) | 12.4 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 145 mm |
| Conformance (Ambient conditions) | CE-compliant |
| UL, USA/Canada (Ambient conditions) | Class I, Div. 2, Groups A, B, C, D |
| Weight per Piece (excluding packing) | 103.410 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Nominal current IN (Ambient conditions) | 4 A |
| Nominal voltage UN (Ambient conditions) | 250 V |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 60 °C |
| Flammability rating according to UL 94 (General) | V0 |
| Housing insulation material (Ambient conditions) | PBT |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Flammability rating according to UL 94 (Ambient conditions) | V0 |
Technical specifications and performance data