| Parameter | Value |
|---|---|
| GTIN | 4017918956639 |
| Orderkey | 2865120 |
| Catalog page | Page 464 (IF-2009) |
| Depth (Note) | 147 mm |
| Packing unit | 1 pc |
| Width (Note) | 12.4 mm |
| Height (Note) | 145 mm |
| (Safety data) | II 3 G Ex nAC IIC T4 X |
| Country of origin | DE (Germany) |
| (Connection data) | II 3 G Ex nAC IIC T4 X |
| ATEX (Safety data) | II (1) G [Ex ia] IIC |
| Custom tariff number | 85364190 |
| (Ambient conditions) | Operation via external switching contact, switch closed: Relay picks up; switch open: Relay drops out |
| ATEX (Connection data) | II (1) G [Ex ia] IIC |
| Color (Connection data) | green |
| Conformance (Safety data) | CE-compliant |
| Contact type (Input data) | 1 PDT |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Conformance (Connection data) | CE-compliant |
| Contact material (Input data) | AgNi, + 5 µm Au |
| Designation (Connection data) | Output/supply |
| Switching output (Input data) | Relay output |
| Connection method (Power supply) | Plug connection |
| Status display (Connection data) | Green LED (supply voltage) |
| Degree of protection (Dimensions) | IP20 |
| No. of channels (Connection data) | 1 |
| Housing material (Connection data) | PBT and polyamide PA non-reinforced |
| Supply voltage range (Output data) | 20 V DC ... 30 V DC |
| Operating mode (Ambient conditions) | Can be adjusted via a slide switch in the front of the housing |
| Mechanical service life (Input data) | 3x 106cycles |
| Weight per Piece (excluding packing) | 67.020 g |
| Service life, electrical (Input data) | 50000 cycles (at 24 V DC / 10 A / 85 °C) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Electrical isolation (Connection data) | 375 V (Peak value as per EN 50020 / EN 60079-11) |
| Maximum switching voltage (Input data) | 30 V DC |
| Contact transition resistor (Input data) | ≤ 0.1 Ω |
| Limiting continuous current (Input data) | 300 mA (when intrinsically safe circuits are connected) |
| Safety-related maximum voltage Um (General) | 250 V AC |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 55 °C |
| Available input sources (Ambient conditions) | External voltage actuated operation; 4 V DC < Us< 30 V DC: Relay picks up; Us< 2 V DC: Relay drops out |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Flammability rating according to UL 94 (Safety data) | V0 |
| Flammability rating according to UL 94 (Connection data) | V0 |
Technical specifications and performance data