Service time: Monday to Friday 9:00-18:00
PC 16 HC/ 2-G-10,16 - PC 16 HC/ 2-G-10,16 1716846 PHOENIX CONTACT PCB base housing, nominal cross-section: 16 mm², colour: green, ..
In Stock Hot Product

PC 16 HC/ 2-G-10,16

PC 16 HC/ 2-G-10,16 1716846 PHOENIX CONTACT PCB base housing, nominal cross-section: 16 mm², colour: green, ..

$0.00USD
3780 in stock
Key Specifications
:1
Step:10.16 mm
Result:Approved Test
Amplitude:0.15 mm (10 Hz ... 60.1 Hz)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
1
Step10.16 mm
ResultApproved Test
Amplitude0.15 mm (10 Hz ... 60.1 Hz)
Width [w]21.56 mm
frequency10 - 150 - 10 Hz
Height [h]27.6 mm
Length [l]32.9 mm
Pin DesignLinear Pin Arrangement
ObservationWEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201
Plug Cycles25
Sweep speed1 octave/min
Product LineCOMBICON Connectors XL
Product TypePrinted circuit board base housing
Hole diameter2.3 mm
Number of rows1
Overall Height23.6 mm
Product Family16 pcs HC/.. -G
Thermal stress105 °C/168 h
Clamping flangewithout
Color (Housing)Green (6021)
Number of poles2
Contact materialCu Alloy
Dimension Scheme
Number of cycles25
Type of mountingWave soldering
Corrosion fatigue0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle
Type of packagingBoxed Packaging
Contact resistance0.235 mΩ
Nominal Current IN76 A
Nominal voltage UN1000 V
Test SpecificationDIN EN 60512-1-1:2003-01
Bearable AC voltage4.26 kV
Degree of pollution3
Insulating materialPA
Weld Pin Length [P]4 mm
Contact Resistance R10.235 mΩ
Contact Resistance R20.212 mΩ
Plug-in force approx.8 N
Nominal voltage (II/2)1000 V
Number of poles tested6
Sizing voltage (III/3)1000 V
Test duration per axis2.5 h
Surface CharacteristicsGalvanically tinned
Insulating material groupI
CTI according to IEC 60112600
Dimensioning voltage (III/2)1000 V
Ambient Temperature (Service)-40 °C ... 105 °C (depending on the rating curve)
Ambient Temperature (Mounting)-5 °C ... 100 °C
Nominal transient voltage (II/2)6 kV
Sizing Insulation Voltage (II/2)1000 V
Nominal transient voltage (III/2)8 kV
Nominal transient voltage (III/3)8 kV
Sizing Insulation Voltage (III/2)1000 V
Sizing Insulation Voltage (III/3)1000 V
Minimum creepage line value (II/2)5.5 mm
Bearable shock voltage at sea level9.8 kV
Metal surface weld area (top layer)Tin (4 - 8 μm Sn)
Minimum creepage line value (III/2)8 mm
Minimum creepage line value (III/3)12.5 mm
Number of Solder Pins Per Potential4
Observation regarding the operationAccording to DIN EN 61984, COMBICON connectors are connectors without switching power (COC). In the event of use as prescribed, they must not be plugged in or unplugged under voltage or load.
Contact Holder UsedRequirement >20 NApproved Test
Insulation Resistance Adjacent Poles> 5 MΩ
Dimensioning transient voltage (II/2)6 kV
Flammability class according to UL 94V0
Power when unplugging by pole approx.6 N
Dimensioning Transient Voltage (III/2)8 kV
Dimensioning transient voltage (III/3)8 kV
Metal surface contact area (top layer)Tin (4 - 8 μm Sn)
Ambient Temperature (Storage/Transport)-40 °C ... 70 °C
Metal Surface Contact Area (Middle Layer)Nickel (1.5 - 4 μm Ni)
Metal Surface Welding Area (Middle Layer)Nickel (1.5 - 4 μm Ni)
Relative humidity of the air (storage/transport)30 % ... 70 %
Ball hardness test temperature according to EN 60695-10-2125 °C
Resistance to leakage currents (DIN EN 60112 (VDE 0303-11))CTI 600
Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2)5.5 mm
Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2)8 mm
minimum value of air insulation distance - non-homogeneous field (III/3)8 mm
Flammability number of GWFI incandescent filaments according to EN 60695-2-12850
Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13775