| Parameter | Value |
|---|---|
| GTIN | Four trillion fifty five billion six hundred twenty six million five hundred thirty eight thousand nine hundred fifty two |
| Note | Manufacturing to the order (no recovery) |
| Order Code | One million thirty three thousand four hundred eighty four |
| Packaging unit | 1 pcs |
| Country of origin | IT (Italy) |
| Height max. (Trade data) | < 2000 m |
| (General characteristics) | IEC 61010-2-032 |
| Number of the customs tariff | Ninety million three hundred nine thousand |
| eCl@ss 9.0 (Classifications) | Twenty seven million two hundred nineteen thousand two hundred ninety |
| (Standards and specifications) | The manufacturer's declaration in the tab "Downloads" contains detailed information on hazardous substances. |
| eCl@ss 10.0.1 (Classifications) | Twenty seven million two hundred nineteen thousand two hundred ninety |
| Position error (Ambient Conditions) | < 1 % |
| Weight per piece (excluding packing) | 0,237 KGM |
| Default linearity (Ambient Conditions) | 0,1 % |
| Protection Type coil meter (Trade data) | IP67 (not evaluated by UL) |
| UL, USA/Canada (General characteristics) | UL 61010 Recognized |
| China RoHS (Standards and specifications) | Period of intended use (EFUP) : 50 years |
| (The output signal of the coil measuring) | 600 V AC (rms CAT IV) |
| Ambient temperature (operation) (Trade data) | -30 °C ... 80 °C (Coil of measure) |
| (General characteristics of the coil measuring) | IEC 61010-2-032 |
| Standards/Requirements (General characteristics) | IEC 61010-1 |
| Humidity of the air eligible (service) (Trade data) | 5 % ... 95 % (no condensation) |
| Ambient temperature (storage/transport) (Trade data) | -40 °C ... 80 °C (Coil of measure) |
| Insulation (The output signal of the coil measuring) | double insulation |
| Output voltage (empty) (Data input coil measurement) | VOUT= M * dI/dt |
| Test voltage (The output signal of the coil measuring) | To 10.45 kV (DC / 1 min) |
| Measurement range of the frequency (Ambient Conditions) | 40 Hz ... 20000 Hz |
| Basic accuracy (The output signal of the coil measuring) | |
| UL, USA/Canada (The output signal of the coil measuring) | UL 61010 Recognized |
| Housing material (The output signal of the coil measuring) | PC |
| Material of coil (The output signal of the coil measuring) | Elastollan |
| The output Signal (at 50 Hz) (Data input coil measurement) | 100 mV (no load, with up to 1000 V) |
| Output voltage (sinusoidal, vacuum) (Data input coil measurement) | 100 mV (VOUT= 2 * π * M * f * I (M = 0,318 µH ; example : 50 Hz ; I = 1000)) |
| Rated insulation voltage (The output signal of the coil measuring) | 1000 V AC (rms CAT III) |
| Coil diameter measurement (The output signal of the coil measuring) | 8.3 mm ±0.2 mm |
| Length of the coil measuring (The output signal of the coil measuring) | 600 mm |
| Length of the signaling line (The output signal of the coil measuring) | 3000 mm |
| Standards/Requirements (General characteristics of the coil measuring) | IEC 61010-1 |
| Structure of the driver signal line (The output signal of the coil measuring) | 2x 0.22 mm (Signal (tinned)) |
Technical specifications and performance data
Installation and operation guide