| Parameter | Value |
|---|---|
| EAN | Four trillion fifty five billion six hundred twenty six million five hundred thirty nine thousand forty one |
| Key order | One million thirty three thousand four hundred eighty two |
| Key selling | CK4A12 - |
| Packing unit | 1 pcs |
| (General data) | IEC 61010-2-032 |
| Tariff number tariff | Ninety million three hundred nine thousand |
| eCl@ss 9.0 (Ratings) | Twenty seven million two hundred nineteen thousand two hundred ninety |
| eCl@ss 10.0.1 (Ratings) | Twenty seven million two hundred nineteen thousand two hundred ninety |
| (Standards and specifications) | You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab |
| UL, USA / Canada (General data) | UL 61010 Recognized |
| (General data coil measurement) | IEC 61010-2-032 |
| Unit weight (excluding packaging) | 372,400 g |
| (Signals output coil measurement) | 600 V AC (rms CAT IV) |
| Max. Height of fixing (Data commercial) | < 2000 m |
| Standards/specifications (General data) | IEC 61010-1 |
| China RoHS (Standards and specifications) | Space of time for the intended use (FEUP): 50 years |
| Position Error (Environmental conditions) | < 1 % |
| Linearity Error (Environmental conditions) | 0,1 % |
| Isolation (Signals output coil measurement) | Double insulation |
| Room temperature (service) (Data commercial) | -30 °C ... 80 °C (Coil of measure) |
| Test voltage (Signals output coil measurement) | 10,45 kV DC / 1 min.) |
| Basic accuracy (Signals output coil measurement) | |
| Material housing (Signals output coil measurement) | PC |
| UL, USA / Canada (Signals output coil measurement) | UL 61010 Recognized |
| Material of the coil (Signals output coil measurement) | Elastollan |
| Output signal (at 50 Hz) (Data input coil measurement) | 100 mV (no load, with 1000 (A) |
| Output voltage (at idle) (Data input coil measurement) | VOUT= M * dI/dt |
| Humidity of air permissible (service) (Data commercial) | 5 % ... 95 % (without condensation) |
| Standards/specifications (General data coil measurement) | IEC 61010-1 |
| Isolation voltage design (Signals output coil measurement) | 1000 V AC (rms CAT III) |
| Ambient temperature (storage / transport) (Data commercial) | -40 °C ... 80 °C (Coil of measure) |
| Degree of protection of the coil measuring (Data commercial) | IP67 (not evaluated by UL) |
| Length of the line signals (Signals output coil measurement) | 10000 mm |
| Range of measurement of frequency (Environmental conditions) | 40 Hz ... 20000 Hz |
| Length of the coil measuring (Signals output coil measurement) | 450 mm |
| Diameter of the coil measuring (Signals output coil measurement) | 8.3 mm ±0.2 mm |
| Construction of the driver signal cable (Signals output coil measurement) | 2x 0.22 mm (Signal (tinned)) |
| Output voltage (sinusoidal, running on empty) (Data input coil measurement) | 100 mV (VOUT= 2 * π * M * f * I (M = 0,318 µH; example: for 50 Hz, I = 1000)) |
Technical specifications and performance data