Service time: Monday to Friday 9:00-18:00
PACT RCP-4000A-UIRO-D190 - PACT RCP-4000A-UIRO-D190 2906233 PHOENIX CONTACT Current transformer
In Stock Hot Product

PACT RCP-4000A-UIRO-D190

PACT RCP-4000A-UIRO-D190 2906233 PHOENIX CONTACT Current transformer

$0.00USD
4556 in stock
Key Specifications
GTIN:4055626048260
Note:Made to Order (non-returnable)
Orderkey:2906233
Catalog page:Page 237 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626048260
NoteMade to Order (non-returnable)
Orderkey2906233
Catalog pagePage 237 (C-5-2017)
Packing unit1 pc
(Dimensions)-40 °C ... 85 °C (Measuring transducer)
Country of originDE (Germany)
Custom tariff number85437090
(Ambient conditions)IEC 61010-2-032
Torque (General data)0.5 Nm ... 0.6 Nm
Depth (Connection data)120.50 mm
Width (Connection data)6.20 mm
Height (Connection data)110.50 mm
Screw thread (General data)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Maximum altitude (Dimensions)> 4000 m
Connection name (General data)Measuring transducer side
(Measuring coil signal output)0 V ... 10.5 V (can be set via software)
Stripping length (General data)10 mm
Conformance (Ambient conditions)CE-compliant
Connection method (General data)Screw connection
Noise emission (Ambient conditions)EN 61000-6-4
Weight per Piece (excluding packing)478.000 g
(Measuring transducer signal output)600 V AC (rms CAT IV)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Power consumption (Key Commercial Data)≤ 1 W (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)
(General data for measuring transducer)IEC 61010-2-032
Degree of pollution (Ambient conditions)2
Electrical isolation (Ambient conditions)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Ambient conditions)II
Standards/regulations (Ambient conditions)IEC 61010-1
Test voltage (General data, measuring coil)3 kV (50 Hz, 1 min.)
Ambient temperature (operation) (Dimensions)-30 °C ... 80 °C (Measuring coil)
Nominal supply voltage (Key Commercial Data)24 V DC
Position error (Measuring transducer supply)< 1 %
Linearity error (Measuring transducer supply)0.1 %
Rated insulation voltage (Ambient conditions)300 V
UL, USA/Canada (General data, measuring coil)UL 508 Listed
Frequency range (General data, measuring coil)16 Hz ... 1000 Hz
Conductor cross section AWG max. (General data)16
Conductor cross section AWG min. (General data)26
Housing material (General data, measuring coil)PBT
Insulation (Measuring transducer signal output)double insulation
Measuring coil degree of protection (Dimensions)IP67 (not assessed by UL)
Conductor cross section solid max. (General data)1.5 mm²
Conductor cross section solid min. (General data)0.2 mm²
Input impedance (Measuring transducer input data)> 100 kΩ
Test voltage (Measuring transducer signal output)10.45 kV (DC / 1 min.)
Coil material (Measuring transducer signal output)Elastollan
Electromagnetic compatibility (Ambient conditions)Conformance with EMC Directive 2004/108/EC
Nominal supply voltage range (Key Commercial Data)9.6 V DC ... 30 V DC
Basic accuracy (Measuring transducer signal output)
UL, USA/Canada (Measuring transducer signal output)UL 61010 Recognized
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C (Measuring coil)
Conductor cross section flexible max. (General data)1.5 mm²
Conductor cross section flexible min. (General data)0.2 mm²
Current output signal (Measuring coil signal output)0 mA ... 20 mA (via DIP switch)
Voltage output signal (Measuring coil signal output)0 V ... 10 V (via DIP switch)
Configurable/programmable (Measuring coil input data)Via DIP switches
Housing material (Measuring transducer signal output)PC
Measuring ranges (current) (Measuring coil input data)100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Measuring transducer degree of protection (Dimensions)IP20
Frequency measuring range (Measuring transducer supply)40 Hz ... 20000 Hz
Input signal (at 50 Hz) (Measuring transducer input data)100 mV (1000 A)
Maximum transmission error (General data, measuring coil)≤ 0.5 % (From the range end value)
Degree of pollution (General data for measuring transducer)2
Length of signal cable (Measuring transducer signal output)3000 mm
Output signal (at 50 Hz) (Measuring transducer signal input)100 mV (no load, at 1,000 A)
Overvoltage category (General data for measuring transducer)II
Length of measuring coil (Measuring transducer signal output)600 mm
Rated insulation voltage (Measuring transducer signal output)1000 V AC (rms CAT III)
Standards/regulations (General data for measuring transducer)IEC 61010-1
Load/output load current output (Measuring coil signal output)≤ 600 Ω (20 mA)
Diameter of measuring coil (Measuring transducer signal output)8.3 mm ±0.2 mm
Typical measuring error (General data for measuring transducer)< 1 %
Conductor structure signal line (Measuring transducer signal output)2x 0.22 mm (Signal (tinned))
Output voltage (in no-load operation) (Measuring transducer signal input)VOUT= M * dI/dt
Output voltage (sinusoidal, in no-load operation) (Measuring transducer signal input)100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))

Product Description

The set consists of a 4-way separation amplifier with screw connection technology and a Rogowski coil with a length of 600 mm and a diameter of 190 mm for AC current measurement in busbars and high-vo
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top