Service time: Monday to Friday 9:00-18:00
PACT RCP-4000A-1A-D140 - PACT RCP-4000A-1A-D140 2904922 PHOENIX CONTACT Current transformer
In Stock Hot Product

PACT RCP-4000A-1A-D140

PACT RCP-4000A-1A-D140 2904922 PHOENIX CONTACT Current transformer

$0.00USD
3688 in stock
Key Specifications
GTIN:4046356900959
Orderkey:2904922
Catalog page:Page 236 (C-5-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356900959
Orderkey2904922
Catalog pagePage 236 (C-5-2017)
Packing unit1 pc
(Dimensions)-25 °C ... 85 °C (Measuring transducer)
Country of originDE (Germany)
Custom tariff number85437090
(Ambient conditions)IV (600 V, to neutral conductor)
Torque (General data)0.5 Nm ... 0.6 Nm
Depth (Connection data)70.40 mm
Width (Connection data)22.50 mm
Height (Connection data)85.00 mm
Screw thread (General data)M3
(Measuring coil input data)107 m (2.5 mm² (AWG 14))
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Maximum altitude (Dimensions)< 2000 m
Connection name (General data)Measuring transducer side
Insulation (Ambient conditions)double insulation
Stripping length (General data)7 mm
Connection method (General data)Screw connection
Load (Measuring coil signal output)0 Ω ... 1.5 Ω
Weight per Piece (excluding packing)440.300 g
(Measuring transducer signal output)600 V AC (rms CAT IV)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Phase angle (Measuring coil input data)< 1 °
Power consumption (Key Commercial Data)4 W
Rated power (Measuring coil input data)1.5 VA
(General data for measuring transducer)0.07 %/K (-20°C ... +10°C; both components have the same ambient temperature)
Degree of pollution (Ambient conditions)2
Overvoltage category (Ambient conditions)III (1,000 V, to neutral conductor)
Standards/regulations (Ambient conditions)IEC 61010-1
Test voltage (General data, measuring coil)1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
Ambient temperature (operation) (Dimensions)-30 °C ... 80 °C (Measuring coil)
Nominal supply voltage (Key Commercial Data)24 V DC -20 % ... +25 %
Position error (Measuring transducer supply)< 1 %
Linearity error (Measuring transducer supply)0.1 %
UL, USA/Canada (General data, measuring coil)UL 508 Listed
Frequency range (General data, measuring coil)45 Hz ... 65 Hz
Linearity error (General data, measuring coil)< 0.5 % (From the range end value)
Max. current consumption (Key Commercial Data)190 mA
Conductor cross section AWG max. (General data)14
Conductor cross section AWG min. (General data)24
Housing material (General data, measuring coil)Polyamide
Insulation (Measuring transducer signal output)double insulation
Measuring coil degree of protection (Dimensions)IP67 (not assessed by UL)
Conductor cross section solid max. (General data)2.5 mm²
Conductor cross section solid min. (General data)0.2 mm²
Input impedance (Measuring transducer input data)27 kΩ (smallest measuring range)
Test voltage (Measuring transducer signal output)10.45 kV (DC / 1 min.)
Coil material (Measuring transducer signal output)Elastollan
Current consumption (General data, measuring coil)< 190 mA (at 19.2 V)
Insulation (General data for measuring transducer)double insulation
Nominal supply voltage range (Key Commercial Data)19.2 V DC ... 30 V DC
Basic accuracy (Measuring transducer signal output)
UL, USA/Canada (Measuring transducer signal output)UL 61010 Recognized
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C (Measuring coil)
Conductor cross section flexible max. (General data)2.5 mm²
Conductor cross section flexible min. (General data)0.2 mm²
Current output signal (Measuring coil signal output)0 A AC ... 1 A
Configurable/programmable (Measuring coil input data)Via DIP switches
Housing material (Measuring transducer signal output)PC
Measuring ranges (current) (Measuring coil input data)100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Measuring transducer degree of protection (Dimensions)IP20
Frequency measuring range (Measuring transducer supply)40 Hz ... 20000 Hz
Max. detectable harmonics (General data, measuring coil)< 2 kHz
Operating voltage display (General data, measuring coil)Green LED
Input signal (at 50 Hz) (Measuring transducer input data)100 mV (1000 A)
Maximum transmission error (General data, measuring coil)≤ 0.5 % (From the range end value)
Degree of pollution (General data for measuring transducer)2
Length of signal cable (Measuring transducer signal output)3000 mm
Output signal (at 50 Hz) (Measuring transducer signal input)100 mV (no load, at 1,000 A)
Overvoltage category (General data for measuring transducer)III (1,000 V, to neutral conductor)
Length of measuring coil (Measuring transducer signal output)450 mm
Rated insulation voltage (Measuring transducer signal output)1000 V AC (rms CAT III)
Standards/regulations (General data for measuring transducer)IEC 61010-1
Diameter of measuring coil (Measuring transducer signal output)8.3 mm ±0.2 mm
Typical measuring error (General data for measuring transducer)< 1 %
Temperature coefficients (General data for measuring transducer)0.005 %/K (+10°C ... +70°C; both components have the same ambient temperature)
Conductor structure signal line (Measuring transducer signal output)2x 0.22 mm (Signal (tinned))
Max. distances for copper cables at PN max (Measuring coil input data)32 m (0.75 mm² (AWG 20))
Output voltage (in no-load operation) (Measuring transducer signal input)VOUT= M * dI/dt
Output voltage (sinusoidal, in no-load operation) (Measuring transducer signal input)100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))

Product Description

Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Rogowski coil length: 450 mm, diameter: 140 mm. Signal line length: 3 m. The Rogowski coil measures AC current from b
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top