Service time: Monday to Friday 9:00-18:00
PACT RCP-4000A-1A-D140-3M-UV - PACT RCP-4000A-1A-D140-3M-UV 1058044 PHOENIX CONTACT Set consisting of one 1 A measuring transducer and one ..
In Stock Hot Product

PACT RCP-4000A-1A-D140-3M-UV

PACT RCP-4000A-1A-D140-3M-UV 1058044 PHOENIX CONTACT Set consisting of one 1 A measuring transducer and one ..

$0.00USD
3227 in stock
Key Specifications
GTIN:4055626702261
Orderkey:1058044
Catalog page:Page 224 (C-5-2019)
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626702261
Orderkey1058044
Catalog pagePage 224 (C-5-2019)
Packing unit1
(Dimensions)-25 °C ... 85 °C (Measuring transducer)
ETIM 6.0 (eCl@ss)EC002048
ETIM 7.0 (eCl@ss)EC002048
(Connection data)IV (600 V, to neutral conductor)
Custom tariff number85437090
Torque (General data)0.5 Nm ... 0.6 Nm
Depth (Key Commercial Data)70.4 mm
Screw thread (General data)M3
Width (Key Commercial Data)22.5 mm
(Measuring coil input data)107 m (2.5 mm² (AWG 14))
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)85 mm
Insulation (Connection data)double insulation
eCl@ss 4.0 (Classifications)27210900
eCl@ss 4.1 (Classifications)27210900
eCl@ss 5.0 (Classifications)27210900
eCl@ss 5.1 (Classifications)27210900
eCl@ss 6.0 (Classifications)27210900
eCl@ss 7.0 (Classifications)27210902
eCl@ss 9.0 (Classifications)27210902
Maximum altitude (Dimensions)< 2000 m
Connection name (General data)Measuring transducer side
Stripping length (General data)7 mm
Connection method (General data)Screw connection
Pollution degree (Connection data)2
Load (Measuring coil signal output)0 Ω ... 1.5 Ω
(Measuring transducer signal output)600 V AC (rms CAT IV)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Overvoltage category (Connection data)III (1000 V, to neutral conductor)
Power consumption (Ambient conditions)4 W
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Phase angle (Measuring coil input data)< 1 °
Rated power (Measuring coil input data)1.5 VA
Standards/regulations (Connection data)IEC 61010-1
(General data for measuring transducer)0.07 %/K (-20°C ... +10°C; both components have the same ambient temperature)
Conductor cross section AWG (General data)24 ... 14
Nominal supply voltage (Ambient conditions)24 V DC -20 % ... +25 %
Test voltage (General data, measuring coil)1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
Ambient temperature (operation) (Dimensions)-30 °C ... 80 °C (Measuring coil)
Conductor cross section solid (General data)0.2 mm² ... 2.5 mm²
Position error (Measuring transducer supply)< 1 %
Linearity error (Measuring transducer supply)0.1 %
Max. current consumption (Ambient conditions)190 mA
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
UL, USA/Canada (General data, measuring coil)UL 508 Listed
Frequency range (General data, measuring coil)45 Hz ... 65 Hz
Linearity error (General data, measuring coil)< 0.5 % (From the range end value)
Conductor cross section flexible (General data)0.2 mm² ... 2.5 mm²
Housing material (General data, measuring coil)Polyamide
Insulation (Measuring transducer signal output)double insulation
Measuring coil degree of protection (Dimensions)IP67 (not assessed by UL)
Input impedance (Measuring transducer input data)27 kΩ (smallest measuring range)
Nominal supply voltage range (Ambient conditions)19.2 V DC ... 30 V DC
Test voltage (Measuring transducer signal output)10.45 kV (DC / 1 min.)
Coil material (Measuring transducer signal output)Elastollan
Current consumption (General data, measuring coil)< 190 mA (at 19.2 V)
Insulation (General data for measuring transducer)double insulation
Basic accuracy (Measuring transducer signal output)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C (Measuring coil)
Current output signal (Measuring coil signal output)0 A AC ... 1 A
Configurable/programmable (Measuring coil input data)Via DIP switches
Housing material (Measuring transducer signal output)PC
Measuring ranges (current) (Measuring coil input data)100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Measuring transducer degree of protection (Dimensions)IP20
Frequency measuring range (Measuring transducer supply)40 Hz ... 20000 Hz
Max. detectable harmonics (General data, measuring coil)< 2 kHz
Operating voltage display (General data, measuring coil)Green LED
Input signal (at 50 Hz) (Measuring transducer input data)100 mV (1000 A)
Maximum transmission error (General data, measuring coil)≤ 0.5 % (From the range end value)
Length of signal cable (Measuring transducer signal output)3000 mm
Output signal (at 50 Hz) (Measuring transducer signal input)100 mV (no load, at 1,000 A)
Length of measuring coil (Measuring transducer signal output)450 mm
Rated insulation voltage (Measuring transducer signal output)1000 V AC (rms CAT III)
Standards/regulations (General data for measuring transducer)IEC 61010-1
Diameter of measuring coil (Measuring transducer signal output)8.3 mm ±0.2 mm
Typical measuring error (General data for measuring transducer)< 1 %
Temperature coefficients (General data for measuring transducer)0.005 %/K (+10°C ... +70°C; both components have the same ambient temperature)
Conductor structure signal line (Measuring transducer signal output)2x 0.22 mm (Signal (tinned))
Max. distances for copper cables at PN max (Measuring coil input data)32 m (0.75 mm² (AWG 20))
Output voltage (in no-load operation) (Measuring transducer signal input)VOUT= M * dI/dt
Output voltage (sinusoidal, in no-load operation) (Measuring transducer signal input)100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))

Product Description

Set consisting of a 1 A measurement transducer and a Rogowski coil resistant to ultraviolet rays with signal line. Rogowski coil length: 450 mm, diameter: 140 mm. Signal line length: 3 m. The coil mea
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top