| Parameter | Value |
|---|---|
| No (Relays with forcibly guided contacts) | 4 poles |
| Load (Relays with forcibly guided contacts) | Resistive load (cosφ= 1) |
| Type (Relays with forcibly guided contacts) | Sealing |
| 24 VDC (Relays with forcibly guided contacts) | 4 poles: 15 mA6 poles: 20.8 mA |
| 6 poles (Relays with forcibly guided contacts) | P7SA-14P |
| Mounting (Relays with forcibly guided contacts) | Terminal type |
| Standard (Relays with forcibly guided contacts) | Flux-tight |
| Durability (Relays with forcibly guided contacts) | Mechanical |
| Electrical (Relays with forcibly guided contacts) | 100,000 operations min. (at the rated load and approx. 1,800 operations/hr) |
| Rated load (Relays with forcibly guided contacts) | 6 A at 250 VAC, 6 A at 30 VDC |
| Back-mounting (Relays with forcibly guided contacts) | PCB terminals |
| Rated voltage (Relays with forcibly guided contacts) | Rated current |
| Release time1 (Relays with forcibly guided contacts) | 20 ms max. |
| Front-mounting (Relays with forcibly guided contacts) | Push-In Plus terminals |
| Response time1 (Relays with forcibly guided contacts) | 10 ms max.(The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.) |
| Operating time2 (Relays with forcibly guided contacts) | 20 ms max. |
| Screw terminals (Relays with forcibly guided contacts) | Yes |
| 3PST-NO, 3PST-NC (Relays with forcibly guided contacts) | G7SA-3A3B |
| 4PST-NO, DPST-NC (Relays with forcibly guided contacts) | G7SA-4A2B |
| Ambient humidity (Relays with forcibly guided contacts) | Operating: 35 to 85% |
| DPST-NO, DPST-NC (Relays with forcibly guided contacts) | G7SA-2A2B |
| Approved standards (Relays with forcibly guided contacts) | EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14 |
| Contact resistance (Relays with forcibly guided contacts) | 100 mΩ max. (The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.) |
| Rated carry current (Relays with forcibly guided contacts) | 6 A |
| Ambient temperature6 (Relays with forcibly guided contacts) | Operating: −40 to 85°C (with no icing or condensation) |
| Dielectric strength34 (Relays with forcibly guided contacts) | Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min(2,500 VAC between poles 3-4 in 4-pole Relays or poles 3-5, 4-6, and 5-6 in 6-pole Relays.)Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min |
| Insulation resistance (Relays with forcibly guided contacts) | 100 MΩ min. (at 500 VDC) (The insulation resistance was measured with a 500 VDC megger at the same places that the dielectric strength wasmeasured.) |
| Max. switching current (Relays with forcibly guided contacts) | 6 A |
| Max. switching voltage (Relays with forcibly guided contacts) | 250 VAC, 125 VDC |
| Min. permissible load5 (Relays with forcibly guided contacts) | 5 VDC, 1 mA (reference value) |
| Max. switching capacity (reference value) (Relays with forcibly guided contacts) | 1,500 VA, 180 W |
Technical specifications and performance data
Installation and operation guide