| Parameter | Value |
|---|---|
| AC (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 24 V, 100 V, 110 V, 120 V, 200 V, 220 V, 230 V, 240 V |
| DC (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 12 V, 24 V, 48 V, 110 V, 220 V |
| NC (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | − |
| Load (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Resistive load |
| Model (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Models for DC Loads |
| Screw (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Soldering |
| Socket (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Clip (set= 2 pcs.) |
| P7MF-06 (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | P7MF-06-D |
| DIN rail (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | PCB |
| L/R = 7 ms (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | DC13 class |
| Rated load (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | NO |
| Contact form (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | SPST-NO |
| Release time (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 20 ms max. |
| Rated voltage (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Must operate voltage |
| Operating time (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | AC: 20 ms max., DC: 30 ms max. |
| MKS1XT(I)(N)-10 (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | MKS2XT(I)(N)-11 |
| 25% min. (50 Hz) (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 2.7 VA (50 Hz) |
| Contact material (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | AgSnIn |
| SPST-NO (1-pole) (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | yes |
| No built-in diode (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Built-in diode |
| Ambient temperature (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | Operating: −40 to 60°C (with no icing or condensation) |
| Dielectric strength (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 2,500 VAC (coil-contact) |
| Rated carry current (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | NO |
| Mechanical endurance (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 1,000,000 operations min. (at 18,000 operations/hr) |
| Size in mm (H×W×D) (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 34.5×34.5×52.1 |
| Contact configuration (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | NO |
| Electrical endurance3 (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | 100.000 operations min. (at rated load and maximum switching frequency) |
| Max. switching current (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | NO |
| Max. switching voltage (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | NO |
| SPST-NO/SPST-NC (2-pole) (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | yes |
| Max. switching capacity (reference value) (DC-switching relay that can switch 220 VDC, 10 A (resistive load)) | NO |
Technical specifications and performance data