Service time: Monday to Friday 9:00-18:00
OTTAD 6/SB-P/P - OTTAD 6/SB-P/P 1033182 PHOENIX CONTACT Feed-through terminal block, With test socket screws for insertion of..
In Stock Hot Product

OTTAD 6/SB-P/P

OTTAD 6/SB-P/P 1033182 PHOENIX CONTACT Feed-through terminal block, With test socket screws for insertion of..

$0.00USD
3789 in stock
Key Specifications
GTIN:4055626537887
Orderkey:1033182
(Drawings):6 mm² / 1.4 kg
Catalog page:Page 567 (C-1-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626537887
Orderkey1033182
(Drawings)6 mm² / 1.4 kg
Catalog pagePage 567 (C-1-2019)
Packing unit1 pc
Width (General)11 mm
Color (Drawings)gray
Length (General)79.2 mm
UNSPSC 11 (ETIM)39121410
Country of originIN (India)
ETIM 2.0 (eCl@ss)EC000902
ETIM 3.0 (eCl@ss)EC000902
ETIM 4.0 (eCl@ss)EC000902
ETIM 5.0 (eCl@ss)EC000897
ETIM 6.0 (eCl@ss)EC000897
ETIM 7.0 (eCl@ss)EC000897
Note (Dimensions)Connection bolts
UNSPSC 13.2 (ETIM)39121410
UNSPSC 18.0 (ETIM)39121410
UNSPSC 19.0 (ETIM)39121410
UNSPSC 20.0 (ETIM)39121410
UNSPSC 21.0 (ETIM)39121410
UNSPSC 6.01 (ETIM)30211811
Setpoint (Drawings)5 N
UNSPSC 12.01 (ETIM)39121410
ASD level (Drawings)6.12 (m/s2)2/Hz
Custom tariff number85369010
UNSPSC 7.0901 (ETIM)39121410
Shock form (Drawings)Half-sine
Height NS 32 (General)57 mm
Minimum order quantity50 pc
Acceleration (Drawings)30g
Connection (Dimensions)1 level
Test spectrum (Drawings)Service life test category 2, bogie-mounted
End cover width (General)1.5 mm
Height NS 35/15 (General)59.5 mm
Screw thread (Dimensions)M4
Shock duration (Drawings)18 ms
Test frequency (Drawings)f1= 5 Hz to f2= 250 Hz
Bolt diameter (Dimensions)4 mm
Height NS 35/7,5 (General)52 mm
Open side panel (Drawings)Yes
Test directions (Drawings)X-, Y- and Z-axis (pos. and neg.)
Number of levels (Drawings)1
Finger protection (Drawings)Not guaranteed
Shock test result (Drawings)Test passed
eCl@ss 4.0 (Classifications)27141126
eCl@ss 4.1 (Classifications)27141126
eCl@ss 5.0 (Classifications)27141126
eCl@ss 5.1 (Classifications)27141126
eCl@ss 6.0 (Classifications)27141126
eCl@ss 7.0 (Classifications)27141126
eCl@ss 8.0 (Classifications)27141120
eCl@ss 9.0 (Classifications)27141120
Bending test turns (Drawings)135
Nominal current IN (Drawings)41 A
Nominal voltage UN (Drawings)1000 V (the nominal voltage applies to insulated cable lugs)
Short-time current (Drawings)0.72 kA
Connection method (Dimensions)Bolt connection
Degree of pollution (Drawings)3
Insulating material (Drawings)PA
Rated surge voltage (Drawings)8 kV
Tensile test result (Drawings)Test passed
Maximum load current (Drawings)41 A (with 6 mm² conductor cross section)
Overvoltage category (Drawings)III
Tight fit on carrier (Drawings)NS 32/NS 35
Hole diameter, min. (Dimensions)4.3 mm
Nominal cross section (Drawings)6 mm²
Number of connections (Drawings)2
Result of bending test (Drawings)Test passed
Result of thermal test (Drawings)Test passed
Test duration per axis (Drawings)5 h
Cable lug width, max. (Dimensions)9.6 mm
Tightening torque max (Dimensions)1.8 Nm
Tractive force setpoint (Drawings)80 N
Tightening torque, min (Dimensions)1.5 Nm
Weight per Piece (excluding packing)0.000 g
Requirements, voltage drop (Drawings)≤ 3.2 mV
Back of the hand protection (Drawings)guaranteed
Bending test rotation speed (Drawings)10 rpm
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Result of voltage-drop test (Drawings)Test passed
Surge voltage test setpoint (Drawings)9.8 kV
Result of surge voltage test (Drawings)Test passed
NF F16-101, NF F10-102 Class F (Drawings)2
NF F16-101, NF F10-102 Class I (Drawings)2
Number of shocks per direction (Drawings)3
Result of tight fit on support (Drawings)Test passed
Short circuit stability result (Drawings)Test passed
Test specification, shock test (Drawings)DIN EN 50155 (VDE 0115-200):2008-03
Note regarding shock protection (Drawings)Electric shock protection only with insulated cable lug guaranteed.
Result of temperature-rise test (Drawings)Test passed
Oxygen index (DIN EN ISO 4589-2) (Drawings)>32 %
Conductor cross section AWG max. (Dimensions)12
Conductor cross section AWG min. (Dimensions)26
Connection in acc. with standard (Dimensions)IEC 60947-7-1
Shock protection test specification (Drawings)IEC 60529:2001-02
Conductor cross section solid max. (Dimensions)6 mm²
Conductor cross section solid min. (Dimensions)0.1 mm²
Conductor cross section tensile test (Drawings)6 mm²
Flame test method (DIN EN 60695-11-10) (Drawings)V0
Flammability rating according to UL 94 (Drawings)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Drawings)passed
Conductor cross section flexible max. (Dimensions)6 mm²
Conductor cross section flexible min. (Dimensions)0.1 mm²
Connection in acc. with standard (Connection data)IEC 60947-7-1
Oscillation, broadband noise test result (Drawings)Test passed
Power frequency withstand voltage setpoint (Drawings)2.2 kV
Surface flammability NFPA 130 (ASTM E 162) (Drawings)passed
Bending test conductor cross section/weight (Drawings)0.14 mm² / 0.2 kg
Cable lug connection according to standard (Dimensions)DIN 46237:1970-07
Max. AWG conductor cross section, flexible (Dimensions)10
Min. AWG conductor cross section, flexible (Dimensions)26
Conductor cross section short circuit testing (Drawings)6 mm²
Flammability rating according to UL 94 (Connection data)V0
Max. cross section for cable lug connection (Dimensions)2.5 mm²
Min. cross section for cable lug connection (Dimensions)0.5 mm²
Static insulating material application in cold (Drawings)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Drawings)Test passed
Maximum power dissipation for nominal condition (Drawings)1.31 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Drawings)28 MJ/kg
Result of power-frequency withstand voltage test (Drawings)Test passed
Test specification, oscillation, broadband noise (Drawings)DIN EN 50155 (VDE 0115-200):2008-03
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Drawings)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Drawings)passed
Relative insulation material temperature index (Elec., UL 746 B) (Drawings)130 °C
Proof of thermal characteristics (needle flame) effective duration (Drawings)30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Drawings)130 °C
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.1 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Drawings)Test passed

Product Description

Feed-in terminal, with threaded sockets for test sockets to accommodate test pins, nominal voltage: 1000 V, nominal current: 41 A, number of connections: 2, connection type: Stud connection, 1st floor
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Circuit diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top