| Parameter | Value |
|---|---|
| GTIN | 4017918820763 |
| Orderkey | 2967989 |
| (General) | EN 50178 |
| Catalog page | Page 394 (C-5-2017) |
| Packing unit | 10 pc |
| (Input data) | Surge protection |
| (Output data) | EN 50178 |
| Country of origin | HU (Hungary) |
| Custom tariff number | 85364190 |
| Insulation (General) | Basic insulation |
| Designation (General) | Standards/regulations |
| Minimum order quantity | 10 pc |
| Designation (Output data) | Standards/regulations |
| Depth (Key Commercial Data) | 15 mm |
| Output circuit (Input data) | 2-wire, floating |
| Width (Key Commercial Data) | 5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 28 mm |
| Operating mode (Output data) | 100% operating factor |
| Degree of pollution (General) | 2 |
| Overvoltage category (General) | III |
| Mounting position (Output data) | any |
| Standards/regulations (General) | IEC 60664 |
| Type of protection (Input data) | Reverse polarity protection |
| Degree of pollution (Output data) | 2 |
| Output voltage range (Input data) | 3 V DC ... 33 V DC |
| Degree of protection (Output data) | RT III (wash-proof) |
| Overvoltage category (Output data) | III |
| Assembly instructions (Output data) | In rows with zero spacing |
| Maximum inrush current (Input data) | 15 A (10 ms) |
| Standards/regulations (Output data) | IEC 60664 |
| Weight per Piece (excluding packing) | 3.500 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Test voltage input/output (Output data) | 2.5 kV (50 Hz, 1 min.) |
| Input voltage range (Ambient conditions) | 4 V DC ... 6 V DC |
| Limiting continuous current (Input data) | 3 A (see derating curve) |
| Connection in acc. with standard (General) | CUL |
| Typical response time (Ambient conditions) | 20 µs (at UN) |
| Typical turn-off time (Ambient conditions) | 300 µs (at UN) |
| Transmission frequency (Ambient conditions) | 300 Hz |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C |
| Nominal input voltage UN (Ambient conditions) | 5 V DC |
| Typical input current at UN (Ambient conditions) | 9 mA |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 70 °C |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.2 |
| Switching threshold "1" signal voltage (Ambient conditions) | ≥ 2.5 V |
| Power dissipation for nominal condition (Ambient conditions) | 0.05 W |
| Switching threshold "0" signal, voltage (Ambient conditions) | ≤ 0.8 V |
| Voltage drop at max. limiting continuous current (Input data) | ≤ 150 mV |
Technical specifications and performance data