| Parameter | Value |
|---|---|
| Item | Specifications |
| Cable | 0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long |
| Output | Relay contact 1 c- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
| Weight | 140 g approx. |
| Details | Retroreflective [Long sensing range] |
| Product | Compact Multi-voltage Photoelectric Sensor |
| Material | Enclosure: PolycarbonateLens: PolycarbonateCover: PolycarbonateFront cover: Acylic |
| Accessory | RF-230 (Reflector): 1 pc. |
| Hysteresis | - |
| Protection | IP66 (IEC) |
| Part Number | NX5-RM7A |
| Product name | Compact Multi-voltage Photoelectric Sensor NX5 |
| Response time | 10 ms or less |
| Sensing range | 0.1 to 7 m 0.328 to 22.966 ft(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. |
| Product Number | NX5-RM7A |
| Sensing object | dia. 50 mm dia. 1.969 in or more opaque or translucent object(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.(Note) Make sure to confirm detection with an actual sensor before use. |
| Supply voltage | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less |
| Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable |
| Power indicator | - |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitting element | Infrared LED (modulated) |
| Pollution degree | 3 (Industrial environment) |
| Shock resistance | 500 m/s2(50 G approx.) in X, Y and Z directions three times each |
| Power consumption | 2 VA or less |
| Ambient illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
| Ambient temperature | -20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office. |
| Operation indicator | Red LED (lights up when the output is ON) |
| Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
| Sensitivity adjuster | - |
| Vibration resistance | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions two hours each |
| Insulation resistance | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals |
| Output:Output operation | Light-ON |
| Voltage withstandability | 1,500 V AC for one min. between power supply and output terminals1,000 V AC for one min. between relay contact terminals |
| CE marking directive compliance | Low Voltage Directive, EMC Directive, RoHS Directive |
| Emitting element:Peak emission wavelength | 880 nm 0.035 mil |
| Automatic Interference prevention function | Incorporated (Two units of sensors can be mounted close together.) |
| Repeatability(perpendicular to sensing axis) | 0.2 mm 0.008 in or less |
Technical specifications and performance data