| Parameter | Value |
|---|---|
| 60 V DC | |
| type | M12 Push-Pull Straight Male / IP67 |
| Runtime | 5.3 ns/m |
| Material | CuSn (Contact) |
| Shielded | Yes |
| Bus system | Ethernet |
| Cable Type | CAT5 Flexible Ethernet, 2-Pair [93E] |
| Application | Standard |
| Line Weight | 42 kg/km |
| Sensor Type | Ethernet |
| Cable Length | 10 m |
| Halogen-free | in accordance with IEC 60754-1 |
| No. of poles | 4 |
| Product Type | Packaged data cable |
| UL AWM Style | 20963 (80 °C / 30 V) |
| Clamping Type | Push-Pull |
| Encoding Type | D (Data) |
| Line Capacity | ca. 45 nF/km (at 1 kHz) |
| Full stranding | 2 paisa with 2 fillers to the core |
| Oil Resistance | according to EN 60811-2-1 |
| AWG Signal Line | 26 |
| Flame Resistance | according to IEC 60332-1-2 |
| Mass Resistivity | ≤ 5 mΩ |
| Rated Current IN | 1.5 A |
| Rated voltage UN | 48 V AC |
| Status Reporting | no |
| Tensile strength | ≤ 80 N |
| Mating resistance | ≤ 100.00 mΩ/m (with 10 MHz) |
| Conductor material | Bare Cu Wire |
| Manoeuvring cycles | ≥ 100 |
| Stranding in pairs | 2 conductors in pairs |
| Conductor structure | 2x2xAWG26/7, SF/UTP |
| Degree of pollution | 3 |
| Dimensioned Drawing | |
| Outer sheath, color | sea blue RAL 5021 |
| Transmission medium | copper |
| Degree of protection | IP67 |
| Overvoltage Category | II |
| Signal Type/Category | Ethernet CAT5 (IEC 11801), 100 MBit/s |
| Insulation Resistance | ≥ 100 MΩ |
| Nominal cable voltage | ≤ 100 V (Peak value, not for high currents) |
| Shielding Attenuation | 3.2 dB (at 1 MHz) |
| Optical Shielded Cover | 70 % |
| Outer Sheath, Material | WHILE |
| Conductor cross-section | 2x 2x 0.14 mm² |
| Return Attenuation (RL) | 23 dB (at 4 MHz) |
| Single conductor, color | white/orange-orange, white/green-green |
| Twisted pair resistance | ≤ 290,00 Ω/km |
| Characteristic Impedance | 100 Ω ±5 Ω (at 100 MHz) |
| Conductor Outer Diameter | 6.4 mm ±0.2 mm |
| Wire/Shield Test Voltage | 700 V (50 Hz, 1 min.) |
| Material, Wire Insulation | PE foam |
| Wire-to-wire test voltage | 700 V (50 Hz, 1 min.) |
| Available Status Indication | no |
| Cable Standards/Regulations | Electrical requirements EN 50288-2-2 |
| Outer sheath wall thickness | 1.2 mm |
| Minimum bending radius, fixed | 4 x D |
| Paraphonic attenuation (NEXT) | 65.3 dB (at 1 MHz) |
| Ambient temperature (operating) | -25 °C ... 85 °C |
| Line Signal Conductor Structure | 7x 0.16 mm |
| Minimum bending radius, movable | 52 mm |
| Minimum bending radius, flexible | 8 x D |
| Ambient temperature (installation) | -20 °C ... 80 °C |
| Wire diameter with insulating sheath | 0.98 mm |
| Permissible current load of the cable | 2 A (according to DIN VDE 0891-1) |
| Combustibility class according to UL 94 | V0 |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Power-sum crosstalk attenuation (PSNEXT) | 62.3 dB (at 1 MHz) |
Technical specifications and performance data