| Parameter | Value |
|---|---|
| 60 V DC | |
| Material | CuSn (Contact) |
| Shielded | Yes |
| Bus system | Ethernet |
| Cable type | CAT5 Flexible Ethernet, 2-Pair [93E] |
| Pair wiring | 2 conductors as pair |
| Plug Cycles | ≥ 100 |
| Sensor Type | Ethernet |
| application | Standard |
| Cable Weight | 42 kg/km |
| Cable length | 10 m |
| Construction | M12 Push-pull / IP67 Straight Connector |
| Line Section | 2x 2x 0.14 mm² |
| Product Type | Ready-made data cable |
| UL AWM Style | 20963 (80 °C / 30 V) |
| Encoding Type | D (Data) |
| Line Capacity | approx. 45 nF/km (at 1 kHz) |
| Total cabling | 2 pairs with 2 fillings as a core |
| Locking system | Push-pull |
| Oil Resistance | according to EN 60811-2-1 |
| Screen dimming | 3.2 dB (with 1 MHz) |
| Self-impedance | 100 Ω ±5 Ω (at 100 MHz) |
| Surge Category | Ii |
| AWG Signal Line | 26 |
| Grip body color | black |
| Number of poles | 4 |
| Conductor Design | 2x2xAWG26/7, SF/UTP |
| Dimension Scheme | |
| Flame Resistance | according to IEC 60332-1-2 |
| Protection Index | IP67 |
| Tensile strength | ≤ 80 N |
| Outer Wrap, Color | aqua blue RAL 5021 |
| Status Indication | No |
| Contact resistance | ≤ 5 mΩ |
| Nominal Current IN | 1 A |
| Nominal voltage UN | 48 V AC |
| Transfer Impedance | ≤ 100.00 mΩ/m (at 10 MHz) |
| Absence of halogens | according to IEC 60754-1 |
| Conductive Material | Naked Cu Conductor |
| Degree of pollution | 3 |
| Signal Transit Time | 5.3 ns/m |
| Transmission Medium | copper |
| Visual Screen Cover | 70 % |
| Cable Outer Diameter | 6.4 mm ±0.2 mm |
| Outer Wrap, Material | PUR |
| Polishing resistance | ≤ 290.00 Ω/km |
| Signal Type/Category | Ethernet CAT5 (IEC 11801), 100 MBit/s |
| Single Driver, Color | white/orange-orange, white/green-green |
| Insulation resistance | ≥ 100 MΩ |
| Line Current Capacity | 2 A (according to DIN VDE 0891-1) |
| Nominal Voltage Cable | ≤ 100 V (Peak value, not suitable for high intensity) |
| Return Attenuation (RL) | 23 dB (at 4 MHz) |
| Wall Thickness Outer Wrap | 1.2 mm |
| Available Status Indication | No |
| Ambient Temperature (Layout) | -20 °C ... 80 °C |
| Ambient Temperature (Service) | -25 °C ... 85 °C |
| Minimum bending radius, fixed | 4 x D |
| Cable Standards/Specifications | Electrical requirements EN 50288-2-2 |
| Material: Conductor Insulation | Foamed PE |
| Test Voltage Conductor/Display | 700 V (50 Hz, 1 min.) |
| Paradiaphonic Attenuation (NEXT) | 65.3 dB (with 1 MHz) |
| Test Voltage Conductor/Conductor | 700 V (50 Hz, 1 min.) |
| Conductor Construction Signal Cable | 7x 0.16 mm |
| Conductor diameter incl. insulation | 0.98 mm |
| Flammability class according to UL 94 | V0 |
| Smaller bending radius, fixed mounting | 26 mm |
| Transmission Characteristics (Category) | CAT5 (IEC 11801:2002) |
| Smaller bending radius, movable mounting | 52 mm |
| Minimum bending radius, flexibly positioned | 8 x D |
| Paradiaphonic Attenuation with Numbered Power (PSNEXT) | 62.3 dB (with 1 MHz) |
Technical specifications and performance data
Installation and operation guide