| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug straight M12 SPEEDCON |
| Coding | X |
| Damping | 0.25 dB (with 1 MHz) |
| Shielded | yes |
| Shielding | Tinned copper braided shield |
| Bus system | Ethernet |
| Cable type | Ethernet BETAtrans®railway application CAT7 |
| Application | Railway applications |
| Coding type | X (Data) |
| Sensor type | Ethernet |
| Cable length | 0.35 m |
| Cable weight | 59 kg/km |
| Halogen-free | in accordance with EN 50267-2-1 |
| Locking type | SPEEDCON |
| Product type | Data cable preassembled |
| Signal speed | 0.78 c |
| Copper weight | 28 kg/km |
| Overall twist | 4 pairs, twisted |
| Twisted pairs | 2 cores to the pair |
| Signal runtime | 4.4 ns/m |
| Status display | No |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| AWG signal line | 26 |
| Cable structure | 4x2xAWG26/7; S/FTP |
| Cable resistance | ≤ 145 Ω/km |
| Flame resistance | in accordance with EN 60332-1-2 |
| Other resistance | Resistant to fuel in accordance with EN 50306-4, 168 hours at 70°C, IRM 903 |
| Tensile strength | ≤ 60 N (temporary) |
| Resistance to oil | in accordance with EN 50306-4, 72 hours at 100°C, IRM 902 |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 0.5 A |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | 60 dB (up to 1000 MHz) |
| Single wire, color | white-blue, white-orange, white-green, white-brown |
| Special properties | HL1-HL3 |
| Coupling resistance | 5.00 mΩ/m (at 10 MHz) |
| Dimensional drawing | |
| Number of positions | 8 |
| Transmission medium | Copper |
| Working capacitance | 44 nF (per kilometer) |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Signal type/category | Ethernet CAT6A, 10 Gbps |
| Standard designation | M12 connector |
| Concentration of fumes | EN 61034-2 |
| External sheath, color | black |
| Nominal voltage, cable | 125 V AC (Uo) |
| Outer sheath, material | PE-X |
| Status display present | No |
| Test voltage Core/Core | 1000 V AC (50 Hz, 1 min.) |
| Type of pair shielding | Aluminum-lined polyester foil |
| Conductor cross section | 4x 2x 0.14 mm² |
| External cable diameter | 6.6 mm ±0.2 mm |
| Return attenuation (RL) | 24 dB (with 1 MHz) |
| Interference suppression | 90 dB (up to 1000 MHz) |
| Material wire insulation | Cell PE |
| Standards/specifications | IEC 61076-2-109 |
| Test voltage Core/Shield | 1000 V AC (50 Hz, 1 min.) |
| Cable type (abbreviation) | 94S |
| Cable insulation resistance | ≥ 5 GΩ*km |
| Crosstalk attenuation (ACR) | 100 dB (with 1 MHz) |
| Wire diameter incl. insulation | 1.05 mm ±0.1 mm |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 7x 0.16 mm |
| Fire protection in rail vehicles | BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) |
| Near end crosstalk attenuation (NEXT) | 100 dB (with 1 MHz) |
| Transmission characteristics (category) | CAT6A |
| Minimum bending radius, fixed installation | 6 x D |
| Power-summated crosstalk attenuation (PS-ACR) | 97 dB (with 1 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 97 dB (with 1 MHz) |
Technical specifications and performance data