| Parameter | Value |
|---|---|
| Ethernet | |
| Type | Plug straight M12 SPEEDCON / IP65 |
| Coding | D |
| Damping | 2 dB (with 1 MHz) |
| Material | CuSn (Contact) |
| Shielded | yes |
| Shielding | Plastic-coated aluminum foil, tinned copper braided shield |
| Bus system | PROFINET |
| Cable type | PROFINET RADOX®railway application CAT5 reinforced |
| Application | Railway applications |
| Coding type | D (Data) |
| Sensor type | PROFINET |
| Cable length | 7 m |
| Cable weight | 81 g/m |
| Halogen-free | in accordance with EN 50267-2-1 |
| Handle color | black |
| Locking type | SPEEDCON |
| Product type | Data cable preassembled |
| Signal speed | 66 c |
| Fume toxicity | BS 6853 B.1 |
| Overall twist | Star quad |
| Status display | No |
| Wave impedance | 100 Ω |
| AWG signal line | 22 |
| Cable structure | 1x4xAWG22/7, SF/TQ |
| Cable resistance | ≤ 54.4 Ω/km |
| Flame resistance | EN 60332-1-2 |
| Other resistance | Resistance to fuels according to IRM 903, 168 h at 70 °C |
| Resistance to oil | according to IRM 902, 72 h at 100 °C |
| Tightening torque | 0.4 Nm |
| Conductor material | silver-plated Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Fume corrosiveness | EN 50267-2-2 |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | 40 dB (30 MHz ≤ f ≤ 100 MHz) |
| Single wire, color | white-blue, orange-yellow |
| Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Test voltage, cable | 2000 V AC (50 Hz, 5 minutes) |
| Transmission medium | Copper |
| Working capacitance | ≤ 65 pF (Line-line) |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Standards/regulations | PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Concentration of fumes | BS 6853 D.8.7 |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | 300 V AC |
| Outer sheath, material | PE-X |
| Status display present | No |
| Conductor cross section | 4x 0.34 mm² |
| External cable diameter | 7.25 mm ±0.3 mm |
| Optical shield covering | 100 % |
| Return attenuation (RL) | 35 dB (at 4 МHz) |
| Thickness, outer sheath | ≥ 0.8 mm |
| Material wire insulation | PE-X |
| Standards/specifications | IEC 61076-2-101 |
| Cable type (abbreviation) | 936 |
| Max. conductor resistance | 54.4 Ω/km |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 1.95 mm |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Conductor structure signal line | 7x 0.25 mm |
| Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
| Remote crosstalk attenuation (FEXT) | 80 dB (with 1 MHz) |
| Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
| Flammability rating according to UL 94 | V0 |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Minimum bending radius, fixed installation | 6 x D |
| Minimum bending radius, flexible installation | 10 x D |