| Parameter | Value |
|---|---|
| GTIN | 4046356933698 |
| Note | Made to Order (non-returnable) |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1411505 |
| Packing unit | 1 pc |
| (Dimensions) | IP67 (M12 connector) |
| (General data) | Zinc die-cast, nickel-plated (Screw connection) |
| Country of origin | PL (Poland) |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Color (General data) | black |
| Custom tariff number | 85444210 |
| (Ambient conditions) | 60 V DC |
| Coding (General data) | D (Data) |
| Torque (General data) | 0.4 Nm |
| Head type (General data) | Plug straight M12 SPEEDCON / IP67 |
| (Standards and Regulations) | -40 °C ... 70 °C (cable, flexible installation) |
| Color (Characteristics head 1) | black |
| Degree of protection (Dimensions) | IP65 (M12 connector) |
| Head type (Characteristics head 1) | free cable end |
| Rated voltage (Ambient conditions) | 48 V AC |
| Material (component) (General data) | CuSn (Contact) |
| Insulation resistance (General data) | ≥ 100 MΩ |
| Weight per Piece (excluding packing) | 153.000 g |
| Length of cable (Key Commercial Data) | 2 m |
| Shielding (Standards and Regulations) | Tinned copper braided shield |
| Cable type (Standards and Regulations) | Sercos III |
| Wire colors (Standards and Regulations) | White, yellow, blue, orange |
| Cable weight (Standards and Regulations) | 68 kg/km |
| Number of positions (Ambient conditions) | 4 |
| UL AWM style (Standards and Regulations) | 21694 (60°C / 600 V) |
| Overall twist (Standards and Regulations) | Star quad |
| Signal type/category (Ambient conditions) | Sercos CAT5 (IEC 11801), 100 Mbps |
| Insertion/withdrawal cycles (General data) | ≥ 100 |
| Signal runtime (Standards and Regulations) | 5.3 ns/m |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-101 |
| Wave impedance (Standards and Regulations) | 100 Ω ±15 Ω (at 100 MHz) |
| AWG signal line (Standards and Regulations) | 22 |
| Cable structure (Standards and Regulations) | 1x4xAWG22/7; SF/TQ |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 90 °C (M12 connector) |
| Flame resistance (Standards and Regulations) | according to UL 1685 (CSA FT 4) |
| Other resistance (Standards and Regulations) | UV resistant According to UL 1581, Section 1200 |
| Resistance to oil (Standards and Regulations) | Resistant to oil to a limited extent |
| Standard designation (Characteristics head 2) | M12 connector |
| Ambient temperature (operation) (General data) | -25 °C ... 90 °C |
| Conductor material (Standards and Regulations) | Tin-plated Cu litz wires |
| Standards/regulations (Characteristics head 2) | IEC 61076-2-101 |
| Coupling resistance (Standards and Regulations) | ≤ 20.00 mΩ/m (at 10 Hz) |
| Conductor resistance (Standards and Regulations) | ≤ 120 Ω/km |
| Signal type/category (Standards and Regulations) | Sercos CAT5 (IEC 11801), 100 Mbps |
| Insulation resistance (Standards and Regulations) | ≥ 0.5 GΩ*km |
| External sheath, color (Standards and Regulations) | signal red RAL 3020 |
| Material, inner sheath (Standards and Regulations) | PVC |
| Nominal voltage, cable (Standards and Regulations) | 600 V |
| Outer sheath thickness (Standards and Regulations) | approx. 0.9 mm |
| Outer sheath, material (Standards and Regulations) | PVC |
| Test voltage Core/Core (Standards and Regulations) | 2000 V (50 Hz, 1 min.) |
| Type of pair shielding (Standards and Regulations) | Aluminum-lined polyester foil |
| Conductor cross section (Standards and Regulations) | 4x 0.34 mm² |
| Test voltage Core/Shield (Standards and Regulations) | 2000 V (50 Hz, 1 min.) |
| Cable type (abbreviation) (Standards and Regulations) | 93K |
| External cable diameter D (Standards and Regulations) | 6.5 mm ±0.2 mm |
| No. of positions (pin connector pattern) (General data) | 4 |
| Material conductor insulation (Standards and Regulations) | PE |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 70 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 7x 0.25 mm |
| Ambient temperature (installation) (Standards and Regulations) | -20 °C ... 60 °C |
| Core diameter including insulation (Standards and Regulations) | approx. 1.55 mm |
| Ambient temperature (storage/transport) (Standards and Regulations) | -50 °C ... 70 °C |
| Minimum bending radius, fixed installation (Standards and Regulations) | 3 x D |
| Minimum bending radius, flexible installation (Standards and Regulations) | 7 x D |
| Stripping length of the sheath (free conductor end) (Characteristics head 1) | 45 mm ±10 mm |