| Parameter | Value |
|---|---|
| GTIN | 4055626809915 |
| Orderkey | 1081292 |
| (Drawings) | |
| Packing unit | 1 |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 60 V DC |
| Note (Ambient conditions) | The cable is 100% electrically tested for continuity. |
| Length of cable (Drawings) | 13.8 m |
| (Standards and Regulations) | -25 °C ... 70 °C (cable, flexible installation) |
| eCl@ss 9.0 (Classifications) | 27060308 |
| Rated voltage (Ambient conditions) | 48 V AC |
| Contact material (Ambient conditions) | CuSn |
| Shielding (Standards and Regulations) | Aluminum-lined polyester foil, tinned copper braided shield |
| Cable type (Standards and Regulations) | PROFINET railway applications |
| Attenuation (Standards and Regulations) | 1.5 dB (with 1 MHz) |
| Standards/specifications (General data) | M12 connector IEC 61076-2-101 |
| Wire colors (Standards and Regulations) | white-blue, orange-yellow |
| Cable weight (Standards and Regulations) | 71 kg/km |
| Degree of pollution (Ambient conditions) | 3 |
| Halogen-free (Standards and Regulations) | According to EN 50267-2-1 |
| Number of positions (Ambient conditions) | 4 |
| Signal speed (Standards and Regulations) | 0.75 c |
| Overall twist (Standards and Regulations) | Star quad |
| Overvoltage category (Ambient conditions) | II |
| Signal type/category (Ambient conditions) | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Cable capacity (Standards and Regulations) | 44 nF/km (core-core) |
| Signal runtime (Standards and Regulations) | 4.4 ns/m |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-101 |
| Wave impedance (Standards and Regulations) | 100 Ω ±5 Ω (f = 100 MHz) |
| AWG signal line (Standards and Regulations) | 22 |
| Cable impedance (Standards and Regulations) | 100 Ω ±15 Ω (f = 0.5 MHz ... 3 MHz) |
| Cable structure (Standards and Regulations) | 1x4xAWG22/7; SF/TQ |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 85 °C (M12 connector) |
| Flame resistance (Standards and Regulations) | according to EN 60332-1-2 |
| Other resistance (Standards and Regulations) | Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903 |
| Return loss (RL) (Standards and Regulations) | 25 dB (with 1 MHz) |
| Contact carrier material (Ambient conditions) | TPU GF |
| Contact surface material (Ambient conditions) | Ni/Au |
| Resistance to oil (Standards and Regulations) | according to EN 60684-2, 72 h at 100 °C, IRM 902 |
| Conductor material (Standards and Regulations) | Tin-plated Cu litz wires |
| Shield attenuation (Standards and Regulations) | 60 dB (up to 1000 MHz) |
| Coupling resistance (Standards and Regulations) | < 13.00 mΩ/m (f = 1 MHz) |
| Conductor resistance (Standards and Regulations) | ≤ 54.4 Ω/km |
| Signal type/category (Standards and Regulations) | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Tensile strength GRP (Standards and Regulations) | ≤ 60 N (temporary) |
| Insulation resistance (Standards and Regulations) | ≥ 5 GΩ*km |
| Concentration of fumes (Standards and Regulations) | EN 61034-2 |
| External sheath, color (Standards and Regulations) | black |
| Nominal voltage, cable (Standards and Regulations) | 125 V |
| Outer sheath thickness (Standards and Regulations) | 1 mm |
| Outer sheath, material (Standards and Regulations) | PE-X |
| Test voltage Core/Core (Standards and Regulations) | 1000 V AC (50 Hz, 1 min.) |
| Conductor cross section (Standards and Regulations) | 4x 0.34 mm² |
| Test voltage Core/Shield (Standards and Regulations) | 1000 V AC (50 Hz, 1 min.) |
| Cable type (abbreviation) (Standards and Regulations) | 939 |
| External cable diameter D (Standards and Regulations) | 6.6 mm ±0.2 mm |
| Flammability rating according to UL 94 (General data) | V0 |
| Material conductor insulation (Standards and Regulations) | Cell PE |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 85 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 7x 0.25 mm |
| Dimensional drawingRJ45 Push-Pull connector, IP67 (Drawings) | |
| Fire protection in rail vehicles (Standards and Regulations) | BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) |
| Core diameter including insulation (Standards and Regulations) | 1.4 mm ±0.1 mm |
| Schematic diagramConnector pin assignment plug RJ45 (Drawings) | |
| Near end crosstalk attenuation (NEXT) (Standards and Regulations) | 76 dB (with 1 MHz) |
| Minimum bending radius, fixed installation (Standards and Regulations) | 5 x D |
| Minimum bending radius, flexible installation (Standards and Regulations) | 6 x D |
| Power-summated near end crosstalk attenuation (PSNEXT) (Standards and Regulations) | 73 dB (with 1 MHz) |
Technical specifications and performance data
Installation and operation guide