| Parameter | Value |
|---|---|
| EAN | Four trillion fifty five billion six hundred twenty six million one hundred thirty five thousand nine hundred eight |
| (Cable) | You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab |
| Key order | One million four hundred eighteen thousand two hundred fifty six |
| Key selling | BF1CJN - |
| Packing unit | 1 pcs |
| (General data) | Die-cast zinc, nickel-Connection by screw) |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Space of time for the intended use (FEUP): 50 years |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| UNSPSC 13.2 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| Color (General data) | black |
| Tariff number tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| eCl@ss 5.1 (Ratings) | Twenty seven million two hundred fifty thousand one hundred seven |
| eCl@ss 6.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 8.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 (Ratings) | Twenty seven million sixty thousand three hundred eleven |
| Encoding (General data) | D (Data) |
| (Values nominal head 1) | Die-cast zinc, nickel-Connection by screw) |
| (Environmental conditions) | 60 V DC |
| Color (Values nominal head 1) | black |
| Cycles of plug (General data) | ≥ 100 |
| Cable length (Data commercial) | 100 m |
| (Standards and specifications) | -40 °C ... 70 °C (cable, available mobile) |
| Encoding (Values nominal head 1) | D (Data) |
| Tightening torque (General data) | 0.4 Nm |
| Unit weight (excluding packaging) | 6.970,900 g |
| Construction header (General data) | Connector straight M12 SPEEDCON / IP67 |
| Insulation resistance (General data) | ≥ 100 MΩ |
| Material (components) (General data) | CuSn (Contact) |
| Room temperature (service) (Measures) | -25 °C ... 90 °C (Connector M12) |
| Cycles of plug (Values nominal head 1) | ≥ 100 |
| Observation (Environmental conditions) | This product complies with the directive PROFINET Cabling and Interconnection Technology Guideline for PROFINET Version 2.00, Order No: some 2,252, chapter 8.2 Connectors for Outside Environment (Balanced cabling) |
| Name of standard (Nominal values 2 head) | Plug-in connector M12 |
| Shielding (Standards and specifications) | Sheet with lined aluminum, mesh of copper wires tinned |
| Room temperature (service) (General data) | -25 °C ... 90 °C |
| Tension sizing (Environmental conditions) | 48 V AC |
| Tightening torque (Values nominal head 1) | 0.4 Nm |
| Attenuation (Standards and specifications) | 2,1 dB (1 MHz) |
| Number of poles (Environmental conditions) | Four |
| Construction header (Values nominal head 1) | Connector straight M12 SPEEDCON / IP67 |
| Material contact (Environmental conditions) | CuSn |
| UL AWM Style (Standards and specifications) | Twenty one thousand six hundred ninety four |
| Cabling total (Standards and specifications) | Fours star |
| Colors driver (Standards and specifications) | White, yellow, blue, orange |
| Impedance own (Standards and specifications) | 100 Ω ±15 Ω (at 100 MHz) |
| Speed signals (Standards and specifications) | 0,66 c |
| Type of cable (Standards and specifications) | PROFINET PVC flexible CAT5 |
| Insulation resistance (Values nominal head 1) | ≥ 100 MΩ |
| Material (components) (Values nominal head 1) | CuSn (Contact) |
| Number of poles (face of plug) (General data) | Four |
| Oil resistance (Standards and specifications) | Oil-resistant with restrictions |
| Other resistors (Standards and specifications) | UV-resistant according to UL 1581, section 1200 |
| Flame resistance (Standards and specifications) | according to UL 1685 (CSA FT 4) |
| Signal cable AWG (Standards and specifications) | Twenty two |
| Signal type/category (Environmental conditions) | PROFINET CAT5 (IEC 11801), 100 MBit/s |
| Outer wrap, color (Standards and specifications) | green RAL 6018 |
| Section of driver (Standards and specifications) | 4x 0,34 mm2 |
| Standards/specifications (Nominal values 2 head) | IEC 61076-2-101 |
| Transfer impedance (Standards and specifications) | ≤ 20,00 mΩ/m (at 10 MHz) |
| Conductive Material (Standards and specifications) | Conductor Cu tinned |
| Cover visual screen (Standards and specifications) | 85 % |
| Rated voltage Cable (Standards and specifications) | 600 V |
| Room temperature (service) (Values nominal head 1) | -25 °C ... 90 °C |
| Weight of the cable (Standards and specifications) | 67 kg/km |
| Current sizing at 40 °C (Environmental conditions) | 4 To |
| Material contact surface (Environmental conditions) | Ni/Au |
| Signal type/category (Standards and specifications) | PROFINET CAT5 (IEC 11801), 100 MBit/s |
| Standards/specifications (Environmental conditions) | Plug-in connector M12 to IEC 61076-2-101 |
| Construction of cable (Standards and specifications) | 1x4xAWG22/7; SF/TQ |
| Insulation resistance (Standards and specifications) | ≥ 500 MΩ*km |
| Material Wrap interior (Standards and specifications) | PVC |
| Outer casing, material (Standards and specifications) | PVC |
| Number of poles (face of plug) (Values nominal head 1) | Four |
| Resistance to polishing (Standards and specifications) | ≤ 120,00 Ω/km |
| Transit time of signals (Standards and specifications) | 5,3 ns/m |
| Material support of contacts (Environmental conditions) | TPU GF |
| Cable type (abbreviation) (Standards and specifications) | 93B |
| Outer diameter of cable D (Standards and specifications) | 6.5 mm ±0.2 mm |
| Wall thickness outer wrap (Standards and specifications) | approx. 0.9 mm |
| Room temperature (service) (Standards and specifications) | -40 °C ... 70 °C (cable, fixed) |
| Room temperature (available) (Standards and specifications) | -20 °C ... 60 °C |
| Material Insulation conductor (Standards and specifications) | PE |
| Test voltage Conductor/Screen (Standards and specifications) | 2000 V (50 Hz, 1 min) |
| Test voltage Conductor/Conductor (Standards and specifications) | 2000 V (50 Hz, 1 min) |
| Attenuation paradiafónica (NEXT) (Standards and specifications) | 80 dB (with 1 MHz) |
| Construction of the driver signal cable (Standards and specifications) | 7x 0.25 mm |
| Ambient temperature (storage / transport) (Standards and specifications) | -50 °C ... 70 °C |
| Diameter of the conductors, insulation included (Standards and specifications) | 1,55 mm |
| Minimum bending radius, placed in a fixed manner (Standards and specifications) | 3 x D |
| Minimum bending radius, placed in a flexible way (Standards and specifications) | 7 x D |