| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug straight M12 / IP67 |
| Coding | X |
| Damping | 3.2 dB (with 1 MHz) |
| Material | CuZn (Contact) |
| Shielded | yes |
| Shielding | Tinned copper braided shield |
| Bus system | Ethernet |
| Cable type | Ethernet drag chain CAT5, 4-pair |
| Coding type | X (Data) |
| Sensor type | Ethernet |
| Acceleration | 5 m/s² |
| Cable weight | 57 kg/km |
| Halogen-free | according to IEC 60754-1 |
| Handle color | black |
| Product type | Data cable preassembled |
| Short symbol | 9YC(ST)11Y |
| UL AWM Style | 20963 (80°C/30 V) |
| Overall twist | Four pairs and four fillers to the core |
| Twisted pairs | 2 cores to the pair |
| Cable capacity | approx. 50 nF/km (at 1 kHz) |
| Signal runtime | 5.3 ns/m |
| Status display | No |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| AWG signal line | 26 |
| Cable structure | 4x2xAWG26/19, S/UTP |
| Loop resistance | ≤ 290.00 Ω/km |
| Traversing rate | 3 m/s |
| Flame resistance | according to IEC 60332-1-2 |
| Tensile strength | ≤ 100 N |
| Resistance to oil | in accordance with EN 60811-2-1 |
| Tightening torque | 0.4 Nm |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Nominal current IN | 0.5 A |
| Nominal voltage UN | 48 V AC |
| Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
| Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
| Dimensional drawing | |
| Number of positions | 8 |
| Transmission medium | Copper |
| Degree of protection | IP67 |
| No. of cable outlets | 1 |
| Signal type/category | Ethernet CAT5 (IEC 11801:2002), 1 Gbps |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| External sheath, color | water blue RAL 5021 |
| Nominal voltage, cable | ≤ 100 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
| Conductor cross section | 4x 2x 0.14 mm² |
| External cable diameter | 6.9 mm +0.1 mm ... 0.2 mm |
| Optical shield covering | 90 % |
| Return attenuation (RL) | 23 dB (at 4 МHz) |
| Thickness, outer sheath | 0.85 mm |
| Material wire insulation | PP |
| Number of bending cycles | 5000000 |
| Standards/specifications | IEC 61076-2-109 |
| Test voltage Core/Shield | 700 V (50 Hz, 1 min.) |
| Cable type (abbreviation) | 94C |
| Cable insulation resistance | ≥ 500 MΩ*km |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 1 mm |
| Ambient temperature (operation) | -25 °C ... 90 °C |
| Conductor structure signal line | 19x 0.10 mm |
| Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 8 x D |
| Minimum bending radius, drag chain applications | 7,5 x D |
| Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |