| Parameter | Value |
|---|---|
| GTIN | 4046356288637 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1561797 |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85444210 |
| Minimum order quantity | 50 pc |
| (Line characteristics) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| (Electrical characteristics) | -20 °C ... 80 °C (cable, flexible installation) |
| (Mechanical characteristics) | IP67 |
| Shielded (Key Commercial Data) | yes |
| China RoHS (Line characteristics) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Line characteristics) | Lead 7439-92-1 |
| Cable diameter (Key Commercial Data) | 6.70 mm |
| Weight per Piece (excluding packing) | 118.100 g |
| Cable structure (Key Commercial Data) | 2x2xAWG26/7; S-FTP |
| Housing material (Ambient conditions) | TPU/PA |
| Length of cable (Key Commercial Data) | 2 m |
| Shielding (Electrical characteristics) | Aluminum-coated foil, tinned copper braided shield |
| Cable type (Electrical characteristics) | PUR ETHERNET 2x2 FLEX |
| Return Loss (Electrical characteristics) | 23 dB (at 4 МHz) |
| Wire colors (Electrical characteristics) | white/orange-orange, white/green-green |
| Cable weight (Electrical characteristics) | 42 kg/km |
| Halogen-free (Electrical characteristics) | according to IEC 60754-1 |
| Number of positions (Key Commercial Data) | 4 |
| UL AWM style (Electrical characteristics) | 20963 (80°C/30 V) |
| Degree of protection (Key Commercial Data) | IP67/IP20 |
| Overall twist (Electrical characteristics) | Two pairs with two fillers to the core |
| Twisted pairs (Electrical characteristics) | 2 cores to the pair |
| External sheath, color (Ambient conditions) | water blue RAL 5021 |
| Outer sheath, material (Ambient conditions) | PUR |
| Signal runtime (Electrical characteristics) | 5.3 ns/m |
| Wave impedance (Electrical characteristics) | 100 Ω ±5 Ω (at 100 MHz) |
| AWG signal line (Electrical characteristics) | 26 |
| Cable structure (Electrical characteristics) | 2x2xAWG26/7; SF/UTP |
| Flame resistance (Electrical characteristics) | according to IEC 60332-1-2 |
| Wave attenuation (Electrical characteristics) | 3.2 dB (with 1 MHz) |
| Resistance to oil (Electrical characteristics) | according to EN 60811-2-1 |
| Cable abbreviation (Electrical characteristics) | 02YS(ST)C11Y |
| Conductor material (Electrical characteristics) | Bare Cu litz wires |
| Coupling resistance (Electrical characteristics) | ≤ 100.00 mΩ/m (at 10 MHz) |
| Transmission medium (Electrical characteristics) | Copper |
| Degree of protection (Mechanical characteristics) | IP20 |
| Insulation resistance (Electrical characteristics) | ≥ 500 MΩ*km |
| External sheath, color (Electrical characteristics) | water blue RAL 5021 |
| Nominal voltage, cable (Electrical characteristics) | ≤ 100 V (Peak value, not for high-power applications) |
| Outer sheath, material (Electrical characteristics) | PUR |
| Test voltage Core/Core (Electrical characteristics) | 700 V (50 Hz, 1 min.) |
| Conductor cross section (Electrical characteristics) | 2x 2x 0.14 mm² |
| External cable diameter (Electrical characteristics) | 6.4 mm ±0.2 mm |
| Optical shield covering (Electrical characteristics) | 70 % |
| Test voltage Core/Shield (Electrical characteristics) | 700 V (50 Hz, 1 min.) |
| Transmission characteristics (category) (Material data) | CAT5 (IEC 11801:2002) |
| Material conductor insulation (Electrical characteristics) | Foamed PE |
| Ambient temperature (operation) (Electrical characteristics) | -40 °C ... 80 °C (cable, fixed installation) |
| Ambient temperature (operation) (Mechanical characteristics) | -20 °C ... 60 °C (cable, fixed installation) |
| Conductor structure signal line (Electrical characteristics) | 7x 0.16 mm |
| Core diameter including insulation (Electrical characteristics) | 0.98 mm |
| Near end crosstalk attenuation (NEXT) (Electrical characteristics) | 65.3 dB (with 1 MHz) |
| Minimum bending radius, fixed installation (Electrical characteristics) | 4 x D |
| Minimum bending radius, flexible installation (Electrical characteristics) | 8 x D |
Technical specifications and performance data
Installation and operation guide