

| Parameter | Value |
|---|---|
| EtherCAT®, 100 MBit/s | |
| Damping | 2.1 dB (at 1 MHz) |
| Material | CuSn (Contact) |
| Shielded | Yes |
| Feed rate | 4 m/s |
| Screening | Aluminum-lined foil, tinned copper wire mesh |
| Bus system | Ethernet |
| Cable type | PROFINET CAT5 drag chain |
| Plug Cycles | ≥ 100 |
| Signal Rate | 0.66 c |
| application | Standard |
| Abbreviation | 2YH(ST)C11Y |
| Acceleration | 4 m/s² |
| Advance path | 10 m |
| Cable Weight | 61 kg/km |
| Cable length | 10 m |
| Construction | M12 / IP67 Straight Connector |
| Line Section | 4x 0.34 mm² |
| Product Type | Ready-made data cable |
| Encoding Type | D (Data) |
| Total cabling | Star Quadretes |
| Bending radius | 100 mm |
| Oil Resistance | according to DIN EN 60811-2-1 |
| Self-impedance | 100 Ω ±15 Ω (to 1 ... 100 MHz) |
| AWG Signal Line | 22 |
| Cable Structure | 1x4xAWG22/7, SF/TQ |
| Grip body color | black |
| Number of poles | 4 |
| Dimension Scheme | |
| Flame Resistance | according to IEC 60332-1-2 |
| Protection Index | IP67 |
| Rules/Provisions | IEC 61076-2-104 |
| Special Features | Electrical properties according to EN 50288-2-2 |
| Tensile strength | ≤ 150 N |
| Torsional Stress | ± 30°/m |
| Other resistances | UV resistant |
| Outer Wrap, Color | green RAL 6018 |
| Status Indication | No |
| Tightening torque | 0.4 Nm |
| Contact resistance | ≤ 5 mΩ |
| Nominal Current IN | 4 A |
| Nominal voltage UN | 30 V AC |
| Transfer Impedance | ≤ 20.00 mΩ/m (at 10 MHz) |
| Absence of halogens | Yes |
| Conductive Material | Tinned Cu Conductor |
| Degree of pollution | 3 |
| Signal Transit Time | 5.3 ns/m |
| Transmission Medium | copper |
| Visual Screen Cover | 85 % |
| Cable Outer Diameter | 6.5 mm ±0.2 mm |
| Material: Inner Wrap | FRNC |
| Outer Wrap, Material | PUR |
| Polishing resistance | ≤ 120.00 Ω/km |
| Signal Type/Category | PROFINET, 100 MBit/s |
| Single Driver, Color | white, yellow, blue, orange |
| Insulation resistance | ≥ 100 MΩ |
| Nominal Voltage Cable | 600V (UL Qualified) |
| Denomination of standard | M8 plug-in connector |
| Number of bending cycles | 3000000 |
| Cable Type (abbreviation) | 93C |
| Wall Thickness Outer Wrap | approx. 0.9 mm |
| Line Insulation Resistance | ≥ 500 MΩ*km |
| Available Status Indication | No |
| Ambient Temperature (Service) | -25 °C ... 90 °C |
| Minimum bending radius, fixed | 5 x D |
| Material: Conductor Insulation | EP |
| Test Voltage Conductor/Display | 2000 V (50 Hz, 1 min.) |
| Paradiaphonic Attenuation (NEXT) | 80 dB (with 1 MHz) |
| Test Voltage Conductor/Conductor | 2000 V (50 Hz, 1 min.) |
| Conductor Construction Signal Cable | 7x 0.25 mm |
| Conductor diameter incl. insulation | 1.5 mm |
| Minimum bending radius, flexibly positioned | 7.5 x D |
Technical specifications and performance data
Installation and operation guide