NBC-M12MSA/ 5,0-93E D-NL - NBC-M12MSA/ 5,0-93E D-NL 1094443 PHOENIX CONTACT Network cable, 4-position, PUR, water blue RAL 5021, Plug s..
In Stock Hot Product

NBC-M12MSA/ 5,0-93E D-NL

NBC-M12MSA/ 5,0-93E D-NL 1094443 PHOENIX CONTACT Network cable, 4-position, PUR, water blue RAL 5021, Plug s..

$0.00USD
4052 in stock
Key Specifications
GTIN:4055626918136
Orderkey:1094443
(Drawings):
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626918136
Orderkey1094443
(Drawings)
Packing unit1
(Dimensions)-5 °C ... 60 °C (cable, flexible installation)
ETIM 6.0 (eCl@ss)EC001262
ETIM 7.0 (eCl@ss)EC001262
Custom tariff number85444290
(Ambient conditions)60 V DC
Coding (General data)A-coded
Shielded (General data)yes
Head type (General data)Plug straight M12
Length of cable (Drawings)5 m
(Standards and Regulations)-20 °C ... 80 °C (cable, flexible installation)
eCl@ss 9.0 (Classifications)27060308
Head type (Characteristics head 1)free cable end
Rated voltage (Ambient conditions)48 V AC
Contact material (Ambient conditions)CuSn
Shielding (Standards and Regulations)Aluminum-coated foil, tinned copper braided shield
Cable type (Standards and Regulations)PUR ETHERNET 2x2 FLEX
Attenuation (Standards and Regulations)3.2 dB (with 1 MHz)
Wire colors (Standards and Regulations)white/orange-orange, white/green-green
Cable weight (Standards and Regulations)42 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)according to IEC 60754-1
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20963 (80°C/30 V)
Overall twist (Standards and Regulations)Two pairs with two fillers to the core
Overvoltage category (Ambient conditions)I
Twisted pairs (Standards and Regulations)2 cores to the pair
Cable capacity (Standards and Regulations)approx. 45 nF/km (at 1 kHz)
Signal runtime (Standards and Regulations)5.3 ns/m
Wave impedance (Standards and Regulations)100 Ω ±5 Ω (at 100 MHz)
AWG signal line (Standards and Regulations)26
Cable structure (Standards and Regulations)2x2xAWG26/7; SF/UTP
Loop resistance (Standards and Regulations)≤ 290.00 Ω/km
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C (cable, fixed installation)
Flame resistance (Standards and Regulations)according to IEC 60332-1-2
Return loss (RL) (Standards and Regulations)23 dB (at 4 МHz)
Contact carrier material (Ambient conditions)PA 6.6
Contact surface material (Ambient conditions)Ni/Au
Resistance to oil (Standards and Regulations)according to EN 60811-2-1
Conductor material (Standards and Regulations)Bare Cu litz wires
Coupling resistance (Standards and Regulations)≤ 100.00 mΩ/m (at 10 MHz)
Signal type/category (Standards and Regulations)Ethernet CAT5 (IEC 11801), 100 Mbps
Tensile strength GRP (Standards and Regulations)≤ 80 N
Insulation resistance (Standards and Regulations)≥ 500 MΩ*km
External sheath, color (Standards and Regulations)water blue RAL 5021
Nominal voltage, cable (Standards and Regulations)≤ 100 V (Peak value, not for high-power applications)
Outer sheath thickness (Standards and Regulations)1.2 mm
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)700 V (50 Hz, 1 min.)
Conductor cross section (Standards and Regulations)2x 2x 0.14 mm²
Optical shield covering (Standards and Regulations)70 %
Standards/specifications (Standards and Regulations)Electrical requirements EN 50288-2-2
Test voltage Core/Shield (Standards and Regulations)700 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations)93E
External cable diameter D (Standards and Regulations)6.4 mm ±0.2 mm
No. of positions (pin connector pattern) (General data)4 (4)
Material conductor insulation (Standards and Regulations)Foamed PE
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)7x 0.16 mm
Ambient temperature (installation) (Standards and Regulations)-20 °C ... 80 °C
Core diameter including insulation (Standards and Regulations)0.98 mm
Current carrying capacity of cable (Standards and Regulations)2 A (according to DIN VDE 0891-1)
Dimensional drawingPlug, M12 x 1, straight, shielded (Drawings)
Flammability rating according to UL 94 (Characteristics head 2)V2
Near end crosstalk attenuation (NEXT) (Standards and Regulations)65.3 dB (with 1 MHz)
Ambient temperature (storage/transport) (Standards and Regulations)-20 °C ... 80 °C
Minimum bending radius, fixed installation (Standards and Regulations)4 x D
Minimum bending radius, flexible installation (Standards and Regulations)8 x D
Power-summated near end crosstalk attenuation (PSNEXT) (Standards and Regulations)62.3 dB (with 1 MHz)

Product Description

Network cable, 4-poles, Straight M12 connector, encoding: A, to free cable end, cable length: 5 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingPlug, M12 x 1, straight, shielded

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top