| Parameter | Value |
|---|---|
| 50 V DC (Power and data) | |
| Type | Plug angled M12 / IP65/IP67 |
| Coding | Y |
| Material | CuZn (Contact) |
| Shielded | yes |
| Bus system | Ethernet |
| Cable type | Ethernet hybrid [94H] |
| Application | Standard |
| Coding type | Y (Hybrid) |
| Sensor type | Ethernet hybrid |
| Cable length | 0.2 m |
| Cable weight | 110 kg/km |
| Halogen-free | according to IEC 60754-1 |
| Handle color | black |
| Product type | Data cable preassembled |
| UL AWM Style | 20233 (80°C/300 V) |
| Overall twist | 1 star quad and 4 wires with 2 fillers |
| Status display | No |
| Wave impedance | 100 Ω ±15 Ω (4 MHz ... 100 MHz) |
| AWG signal line | 26 |
| Loop resistance | ≤ 280.00 Ω/km (Data) |
| Flame resistance | in accordance with UL 1581, Section 1060 |
| Other resistance | Low adhesion |
| Tensile strength | 85 N (in accordance with DIN EN 50565-1 for flexible installation) |
| Resistance to oil | in accordance with IEC 60811-404 |
| Tightening torque | 0.4 Nm |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Nominal current IN | 6 A (Power) |
| Nominal voltage UN | 48 V AC (Power and data) |
| Shield attenuation | 6.2 dB (at 4 МHz) |
| Single wire, color | white/orange, orange, white/green, green, white, blue, brown, black |
| Special properties | Free of substances which would hinder coating with paint or varnish |
| Conductor structure | 1x4x AWG 26+1x4x AWG 18 |
| Dimensional drawing | |
| Max. bending cycles | 2000000 |
| Number of positions | 8 |
| Transmission medium | Copper |
| Working capacitance | nom. 50 nF (per kilometer) |
| Degree of protection | IP65/IP67 |
| No. of cable outlets | 1 |
| Signal type/category | Ethernet hybrid CAT5 (IEC 11801), 100 Mbps |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Differential impedance | 100 Ω ±5 % (at 100 MHz) |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | ≤ 125 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
| Conductor cross section | 4x 0.15 mm² (Data) |
| External cable diameter | 8.8 mm ±0.2 mm |
| Optical shield covering | 85 % |
| Material wire insulation | PP (Data) |
| Standards/specifications | IEC 61076-2-113 |
| Test voltage Core/Shield | 2000 V (50 Hz, 1 min.) |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 1.05 mm (Data) |
| Ambient temperature (operation) | -25 °C ... 90 °C |
| Conductor structure signal line | 19x 0.10 mm |
| Near end crosstalk attenuation (NEXT) | 56.3 dB (at 4 МHz) |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 4 x D |
| Smallest bending radius, fixed installation | 36 mm |
| Minimum bending radius, flexible installation | 8 x D |
| Smallest bending radius, movable installation | 71 mm |