| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug angled M12 / IP67 |
| Coding | D |
| Material | CuZn (Contact) |
| Shielded | yes |
| Bus system | Ethernet |
| Cable type | Ethernet [93P] |
| Coding type | D (Data) |
| Sensor type | Ethernet |
| Cable length | 1 m |
| Handle color | black |
| Locking type | Push Pull |
| Product type | Data cable preassembled |
| Signal speed | 0.6 c |
| UL AWM Style | 2654 (90 °C / 300 V) |
| Overall twist | Two pairs with two fillers to the core |
| Twisted pairs | 2 cores to the pair |
| Signal runtime | 0.4 ns/m |
| Status display | no |
| Wave impedance | 100 Ω ±5 % (at 100 MHz) |
| AWG signal line | 26 |
| Number of slots | 1 |
| Flame resistance | According to VW-1 |
| Other resistance | Resistant to cleaning agents/disinfectants (According to ECOLAB F&E/P3-E No. 40-1) |
| Tensile strength | ≤ 40 N |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Tightening torque | 0.4 Nm |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | 32.00 dB (up to 100 MHz) |
| Single wire, color | white/orange-orange, white/green-green |
| Conductor structure | 2x2xAWG26/7, SF/UTP |
| Degree of pollution | 3 |
| Number of positions | 4 |
| Working capacitance | < 56 nF |
| Degree of protection | IP67 |
| Signal type/category | Ethernet CAT5 (IEC 11801:2002) |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| External sheath, color | water blue RAL 5021 |
| Nominal voltage, cable | ≤ 300 V AC |
| Outer sheath, material | PVC |
| Status display present | No |
| Test voltage Core/Core | 2500 V DC |
| Type of pair shielding | Aluminum-lined polyester foil |
| Conductor cross section | 2x 2x 0.14 mm² |
| External cable diameter | 6.40 mm ±0.2 mm |
| Optical shield covering | 85 % |
| Thickness, outer sheath | ≥ 1.00 mm |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-101 |
| Max. conductor resistance | ≤ 140 Ω/km |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 0.98 mm ±0.05 mm |
| Ambient temperature (operation) | -40 °C ... 90 °C |
| Conductor structure signal line | 7x 0.16 mm |
| Ambient temperature (installation) | 0 °C ... 50 °C |
| Flammability rating according to UL 94 | V2 |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Smallest bending radius, movable installation | 25 mm |
Technical specifications and performance data
Installation and operation guide