| Parameter | Value |
|---|---|
| GTIN | 4055626346007 |
| Note | Made to Order (non-returnable) |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1423514 |
| Packing unit | 1 pc |
| (Dimensions) | 30 V DC |
| (General data) | Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-6 |
| Country of origin | DE (Germany) |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| Custom tariff number | 85444995 |
| Shielding (General data) | Tinned copper braided shield |
| Cable type (General data) | Ethernet for rail applications |
| Attenuation (General data) | 0.25 dB (with 1 MHz) |
| Rated voltage (Dimensions) | 30 V AC |
| Wire colors (General data) | White-blue, white-orange, white-green, white-brown |
| Cable weight (General data) | 59 kg/km |
| Halogen-free (General data) | According to EN 50267-2-1 |
| Signal speed (General data) | 0.78 c |
| Copper weight (General data) | 28 kg/km |
| Overall twist (General data) | 4 pairs, twisted |
| Twisted pairs (General data) | 2 cores to the pair |
| Signal runtime (General data) | 4.4 ns/m |
| Wave impedance (General data) | 100 Ω ±5 Ω (at 100 MHz) |
| AWG signal line (General data) | 26 |
| Cable structure (General data) | 4x2xAWG26/7; S/FTP |
| Flame resistance (General data) | according to EN 60332-1-2 |
| Other resistance (General data) | Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903 |
| Return loss (RL) (General data) | 24 dB (with 1 MHz) |
| Number of positions (Dimensions) | 8 |
| Resistance to oil (General data) | according to EN 60684-2, 72 h at 100 °C, IRM 902 |
| Conductor material (General data) | Tin-plated Cu litz wires |
| Shield attenuation (General data) | 60 dB (up to 1000 MHz) |
| Signal type/category (Dimensions) | Ethernet CAT7, 10 Gbps |
| Coupling resistance (General data) | 5.00 mΩ/m (at 10 MHz) |
| Working capacitance (General data) | 44 nF (per kilometer) |
| Conductor resistance (General data) | ≤ 145 Ω/km |
| Signal type/category (General data) | Ethernet CAT7, 10 Gbps |
| Tensile strength GRP (General data) | ≤ 60 N (temporary) |
| Insulation resistance (General data) | ≥ 5 GΩ*km |
| Weight per Piece (excluding packing) | 5,773.000 g |
| Concentration of fumes (General data) | EN 61034-2 |
| External sheath, color (General data) | black |
| Length of cable (Key Commercial Data) | 100 m |
| Nominal voltage, cable (General data) | 125 V AC (Uo) |
| Outer sheath, material (General data) | PE-X |
| Test voltage Core/Core (General data) | 1000 V AC (50 Hz, 1 min.) |
| Type of pair shielding (General data) | Aluminum-lined polyester foil |
| Conductor cross section (General data) | 4x 2x 0.14 mm² |
| Interference suppression (General data) | 90 dB (up to 1000 MHz) |
| Test voltage Core/Shield (General data) | 1000 V AC (50 Hz, 1 min.) |
| Cable type (abbreviation) (General data) | 94S |
| External cable diameter D (General data) | 6.6 mm ±0.2 mm |
| Crosstalk attenuation (ACR) (General data) | 100 dB (with 1 MHz) |
| Material conductor insulation (General data) | Cell PE |
| Ambient temperature (operation) (General data) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (General data) | 7x 0.16 mm |
| Fire protection in rail vehicles (General data) | BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) |
| Core diameter including insulation (General data) | 1.05 mm ±0.1 mm |
| Near end crosstalk attenuation (NEXT) (General data) | 100 dB (with 1 MHz) |
| Minimum bending radius, fixed installation (General data) | 6 x D |
| Power-summated crosstalk attenuation (PS-ACR) (General data) | 97 dB (with 1 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) (General data) | 97 dB (with 1 MHz) |
Technical specifications and performance data
Installation and operation guide