| Parameter | Value |
|---|---|
| EAN | Four trillion seventeen billion nine hundred eighteen million two hundred sixty four thousand six hundred ninety seven |
| Key order | One million eight hundred fifty one thousand nine hundred forty four |
| Key selling | AAAFBA - |
| Packing unit | 50 pcs |
| Country of origin | (Germany) |
| (Data connection) | CSA |
| Tariff number tariff | Eighty five million three hundred sixty six thousand nine hundred ninety |
| Isolation (Dimensions) | PA |
| Step (Data commercial) | 5 mm |
| Gauge male (Dimensions) | A3 |
| Average (Data commercial) | 75 mm |
| Screw thread (Dimensions) | M3 |
| Number of poles (Dimensions) | Sixteen |
| Length desaislar (Dimensions) | 7 mm |
| Width [ w ] (Data commercial) | 80 mm |
| (Standards and specifications) | You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab |
| Family of articles (Dimensions) | MVSTBU 2,5/..-ST |
| Nominal current IN (Dimensions) | 12 To |
| Type of connection (Dimensions) | Connection by screw with capsule-traction |
| Unit weight (excluding packaging) | 32,897 g |
| Nominal cross section (Dimensions) | 2.5 mm2 |
| Tightening torque max. (Dimensions) | 0.6 Nm |
| Tightening torque min. (Dimensions) | 0.5 Nm |
| Group insulating material (Dimensions) | I |
| Tension and sizing (II/2) (Dimensions) | 630 V |
| Tension and sizing (III/2) (Dimensions) | 320 V |
| Tension and sizing (III/3) (Dimensions) | 320 V |
| Core cross-section rigid min. (Overview) | 0,2 mm2 |
| Section of conductor AWG max. (Overview) | Twelve |
| Section of conductor AWG min. (Overview) | Twenty four |
| China RoHS (Standards and specifications) | Space of time for the intended use (FEUP): 50 years |
| REACh SVHC (Standards and specifications) | Lead 7439-92-1 |
| Section of conductor rigid max. (Overview) | 2.5 mm2 |
| Transient voltage design (II/2) (Dimensions) | 4 kV |
| Connection according to standard (Dimensions) | EN-VDE |
| Section of flexible conductor max. (Overview) | 2.5 mm2 |
| Transient voltage design (III/2) (Dimensions) | 4 kV |
| Transient voltage design (III/3) (Dimensions) | 4 kV |
| Section of flexible conductor, min. (Overview) | 0,2 mm2 |
| Connection according to standard (Data connection) | EN-VDE |
| Class of flammability according to UL 94 (Dimensions) | V0 |
| Class of flammability according to UL 94 (Data connection) | V0 |
| 2 conductors with same cross section, rigid max. (Overview) | 1 mm2 |
| 2 conductors with same cross section, rigid min. (Overview) | 0,2 mm2 |
| 2 conductors with same cross section, flexible max. (Overview) | 1.5 mm2 |
| 2 conductors with same cross section, flexible, min. (Overview) | 0,2 mm2 |
| Section of flexible conductor with toe, with plastic sleeve max. (Overview) | 2.5 mm2 |
| Section of flexible conductor with toe, with plastic sleeve min. (Overview) | 0.25 mm2 |
| Section of flexible conductor with toe cap, without plastic sleeve max. (Overview) | 2.5 mm2 |
| Section of flexible conductor with toe cap, without plastic sleeve min. (Overview) | 0.25 mm2 |
| 2 conductors with same cross section, flexible with AEH without plastic sleeve max. (Overview) | 1 mm2 |
| 2 conductors with same cross section, flexible with AEH without plastic sleeve min. (Overview) | 0.25 mm2 |
| 2 conductors with same cross section, flexible with TWIN-AEH with plastic sleeve max. (Overview) | 1 mm2 |
| 2 conductors with same cross section, flexible with TWIN-AEH with plastic sleeve min. (Overview) | 0.5 mm2 |
Technical specifications and performance data
Installation and operation guide