| Parameter | Value |
|---|---|
| 2.5 mm² / 0.7 kg | |
| Color | gray |
| Depth | 50.8 mm |
| Width | 5.2 mm |
| Height | 63.5 mm |
| Result | Test passed |
| Spectrum | Service life test category 2, bogie-mounted |
| ASD level | 6.12 (m/s²)²/Hz |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| Potentials | 2 |
| Pulse shape | Half-sine |
| Revolutions | 135 |
| Acceleration | 3.12g |
| Product type | Miniature terminal block |
| Screw thread | M3 |
| Mounting type | NS 15 |
| Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Number of rows | 2 |
| Rotation speed | 10 rpm |
| Shock duration | 18 ms |
| Depth on NS 15 | 51.6 mm |
| Nominal current | 22 A (with a 2.5 mm² conductor cross section) |
| Nominal voltage | 500 V |
| Open side panel | Yes |
| Test directions | X-, Y- and Z-axis |
| Stripping length | 7 mm ... 9 mm |
| Time of exposure | 30 s |
| Cross section AWG | (converted acc. to IEC) |
| Tightening torque | 0.5 ... 0.6 Nm |
| Depth on NS 35/15 | 59.8 mm |
| Degree of pollution | 3 |
| Depth on NS 35/7,5 | 52.3 mm |
| Insulating material | PA |
| Number of positions | 2 |
| Maximum load current | 28 A (with 4 mm² conductor cross-section) |
| Overvoltage category | III |
| Nominal cross section | 2.5 mm² |
| Number of connections | 4 |
| Test voltage setpoint | 1.89 kV |
| Test duration per axis | 5 h |
| DIN rail/fixing support | NS 35/7,5 |
| Insulating material group | I |
| Internal cylindrical gage | A3 |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Conductor cross section/weight | 0.2 mm² / 0.2 kg |
| Number of shocks per direction | 3 |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Number of connections per level | 2 |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
| Short-time withstand current 2.5 mm² | 0.3 kA |
| Flammability rating according to UL 94 | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Conductor cross section, flexible [AWG] | 24 ... 14 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| 2 conductors with same cross section, solid | 0.2 mm² ... 1.5 mm² |
| 2 conductors with same cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Static insulating material application in cold | -60 °C |
| Maximum power dissipation for nominal condition | 0.77 W |
| 2 conductors with the same cross-section AWG rigid | 24 ... 16 (converted acc. to IEC) |
| 2 conductors with the same cross-section AWG flexible | 24 ... 16 (converted acc. to IEC) |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 2.5 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 2.5 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1.5 mm² |
Technical specifications and performance data
Installation and operation guide