| Parameter | Value |
|---|---|
| GTIN | 4017918031800 |
| Orderkey | 1765771 |
| Catalog page | Page 264 (C-1-2013) |
| Packing unit | 50 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85366990 |
| (Ambient conditions) | Test passed |
| Minimum order quantity | 50 pc |
| Result (Pull-out test) | Test passed |
| Note (Connection capacity) | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Pitch (Key Commercial Data) | 5 mm |
| Locking (Key Commercial Data) | without |
| No. of cycles (Pull-out test) | 25 |
| Specification (Pull-out test) | IEC 60512-15-1:2008-05 |
| Torque (Electrical parameters) | 0.5 Nm ... 0.6 Nm |
| Pitch (Material data - housing) | 5 mm |
| Rated current (Item properties) | 12 A |
| Dimensional test (Pull-out test) | Test passed IEC 60512-1-2:2002-02 |
| Cold stress (Durability tests (B)) | -40 °C/2 h |
| Screw thread (Key Commercial Data) | M3 |
| Specification (Climatic tests (D)) | IEC 61984:2008-10 |
| Visual examination (Pull-out test) | Test passed IEC 60512-1-1:2002-02 |
| Test force per pos. (Pull-out test) | 40.5 N |
| (Termination and connection method) | 2.5 mm² / flexible / > 50 N |
| Plug-in system (Key Commercial Data) | CLASSIC COMBICON |
| Specification (Durability tests (B)) | ISO 6988:1985-02 |
| Specification (Mechanical tests (A)) | IEC 60512-9-1:2010-03 |
| Weight per Piece (excluding packing) | 3.900 g |
| Dimension a (Material data - housing) | 5 mm |
| Resistance of marking (Pull-out test) | Test passed IEC 60068-2-70:1995-12 |
| Thermal stress (Durability tests (B)) | 100 °C/168 h |
| Type of contact (Key Commercial Data) | Female connector |
| Width [ w ] (Material data - housing) | 10 mm |
| Contact material (Connection capacity) | Cu alloy |
| Height [ h ] (Material data - housing) | 15 mm |
| Length [ l ] (Material data - housing) | 21.3 mm |
| Number of levels (Key Commercial Data) | 1 |
| Connection method (Key Commercial Data) | Screw connection with tension sleeve |
| Corrosive stress (Durability tests (B)) | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Polarization and coding (Pull-out test) | Test passed IEC 60512-13-5:2006-02 |
| Range of articles (Key Commercial Data) | MSTBP 2,5/..-ST |
| Stripping length (Electrical parameters) | 7 mm |
| (Environmental and durability tests (E)) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Number of positions (Key Commercial Data) | 2 |
| Number of potentials (Key Commercial Data) | 2 |
| Drive form screw head (Key Commercial Data) | Slotted (L) |
| Number of connections (Key Commercial Data) | 2 |
| Contact resistance R1 (Mechanical tests (A)) | 1.3 mΩ |
| Contact resistance R2 (Mechanical tests (A)) | 1.4 mΩ |
| Dimensional drawing (Material data - housing) | |
| Insulating material (Material data - contact) | PA |
| Rated surge voltage (III/2) (Item properties) | 4 kV |
| Surface characteristics (Connection capacity) | hot-dip tin-plated |
| Type of packaging (Dimensions for the product) | packed in cardboard |
| Brief article description (Key Commercial Data) | Printed-circuit board connector |
| Diagram (Air clearances and creepage distances) | |
| Pieces per package (Dimensions for the product) | 50 |
| Outer packaging type (Dimensions for the product) | Carton |
| Pull-out test (Termination and connection method) | IEC 60999-1:1999-11 |
| Insertion/withdrawal cycles (Mechanical tests (A)) | 25 |
| Rated insulation voltage (III/2) (Item properties) | 320 V |
| Withdraw strength per pos. approx. (Pull-out test) | 6 N |
| China RoHS (Environmental and durability tests (E)) | Environmentally Friendly Use Period = 50 |
| Insertion strength per pos. approx. (Pull-out test) | 8 N |
| Insulating material group (Material data - contact) | I |
| CTI according to IEC 60112 (Material data - contact) | 600 |
| Conductor cross section solid (Electrical parameters) | 0.2 mm² ... 2.5 mm² |
| Height (without solder pin) (Material data - housing) | 15 mm |
| Ambient temperature (assembly) (Packaging information) | -5 °C ... 100 °C |
| Ambient temperature (operation) (Packaging information) | -40 °C (dependent on the derating curve) |
| Denomination packing units (Dimensions for the product) | Pcs. |
| Conductor cross section flexible (Electrical parameters) | 0.2 mm² ... 2.5 mm² |
| Power-frequency withstand voltage (Durability tests (B)) | 4.8 kV |
| Power-frequency withstand voltage (Mechanical tests (A)) | 2.21 kV |
| Cylindrical gauge a x b / diameter (Electrical parameters) | 2.8 mm x 2.4 mm / 2.5 mm |
| Result, degree of protection, IP code (Climatic tests (D)) | Finger safety with IP20 test finger |
| Conductor cross section AWG / kcmil (Electrical parameters) | 24 ... 12 |
| Metal surface contact area (top layer) (Connection capacity) | Tin (5 - 7 µm Sn) |
| Impulse withstand voltage at sea level (Durability tests (B)) | 2.21 kV |
| Impulse withstand voltage at sea level (Mechanical tests (A)) | 4.8 kV |
| Test for conductor damage and slackening (Ambient conditions) | IEC 60999-1:1999-11 |
| Metal surface terminal point (top layer) (Connection capacity) | Tin (5 - 7 µm Sn) |
| Ambient temperature (storage/transport) (Packaging information) | -40 °C ... 70 °C |
| Flammability rating according to UL 94 (Material data - contact) | V0 |
| Insulating material group (Mechanical tests according to standard) | I |
| 2 conductors with same cross section, solid (Electrical parameters) | 0.2 mm² ... 1 mm² |
| Insulation resistance, neighboring positions (Mechanical tests (A)) | > 1 TΩ |
| Rated surge voltage (II/2) (Mechanical tests according to standard) | 4 kV |
| Rated surge voltage (III/2) (Mechanical tests according to standard) | 4 kV |
| Rated surge voltage (III/3) (Mechanical tests according to standard) | 4 kV |
| 2 conductors with same cross section, flexible (Electrical parameters) | 0.2 mm² ... 1.5 mm² |
| Rated insulation voltage (II/2) (Mechanical tests according to standard) | 630 V |
| Rated insulation voltage (III/2) (Mechanical tests according to standard) | 320 V |
| Rated insulation voltage (III/3) (Mechanical tests according to standard) | 250 V |
| Withdraw strength per pos. approx. (Current carrying capacity / derating curves) | 6 N |
| Insertion strength per pos. approx. (Current carrying capacity / derating curves) | 8 N |
| Glow wire flammability index GWFI according to EN 60695-2-12 (Material data - contact) | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 (Material data - contact) | 775 |
| Contact holder in insert requirements >20 N (Current carrying capacity / derating curves) | Test passed |
| Polarization when inserted requirement >20 N (Current carrying capacity / derating curves) | Test passed |
| Temperature for the ball pressure test according to EN 60695-10-2 (Material data - contact) | 125 °C |
| Conductor cross section / conductor type / tensile force (Termination and connection method) | 0.2 mm² / solid / > 10 N |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical parameters) | 0.25 mm² ... 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Electrical parameters) | 0.25 mm² ... 2.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve (Electrical parameters) | 0.25 mm² ... 1 mm² |
| 2 conductors with same cross section, stranded, with TWIN ferrules with plastic sleeve (Electrical parameters) | 0.5 mm² ... 1.5 mm² |
Technical specifications and performance data
Installation and operation guide