Key Specifications
:Machine building
Note:When establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >320 V.
Color:gray
Depth:32.1 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Machine building
NoteWhen establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >320 V.
Colorgray
Depth32.1 mm
Width6.2 mm
Height38 mm
ResultTest passed
SpectrumService life test category 2, bogie-mounted
ASD level6.12 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 250 Hz
Potentials1
Pulse shapeHalf-sine
Revolutions135
Acceleration3.12g
Product typeMiniature terminal block
Mounting typeNS 15
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Number of rows1
Rotation speed9 rpm
Shock duration18 ms
Depth on NS 1532.6 mm
End cover width2.2 mm
Nominal current32 A
Nominal voltage500 V
Open side panelYes
Test directionsX-, Y- and Z-axis
Stripping length10 mm ... 12 mm
Time of exposure30 s
Cross section AWG(converted acc. to IEC)
Temperature cycles192
Area of applicationRailway industry
Degree of pollution3
Insulating materialPA
Number of positions1
Rated surge voltage6 kV
Maximum load current36 A (bei 6 mm² Leiterquerschnitt starr)
Overvoltage categoryIII
Nominal cross section4 mm²
Test voltage setpoint7.3 kV
Test duration per axis5 h
DIN rail/fixing supportNS 15
Insulating material groupI
Internal cylindrical gageA4
Conductor cross section rigid0.2 mm² ... 6 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight0.2 mm² / 0.2 kg
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Conductor cross section flexible0.2 mm² ... 6 mm²
Connection in acc. with standardIEC 60947-7-1
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Short-time withstand current 4 mm²0.48 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]24 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition1.02 W
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)0.5 mm² ... 1 mm²

Product Description

Mini feed-through terminal block, nom. voltage: 500 V, nominal current: 32 A, number of positions: 1, connection method: Push-in connection, Rated cross section: 4 mm2, cross section: 0.2 mm2 - 6 mm2,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top