| Parameter | Value |
|---|---|
| Fan (Details) | Yes |
| Name (Details) | NMP650 |
| State (Details) | New |
| Stock (Details) | Yes |
| Alarms (Details) | Over Temperature, Output OK |
| Format (Details) | Box |
| Series (Details) | NMP650 |
| Approvals (Details) | EC, EAC, EN60601, UL, UL60601 3rd Edition |
| Power (W) (Details) | 650,00 |
| Subformato (Details) | Grid |
| Width (mm) (Details) | 89.00 |
| Height (mm) (Details) | 41.00 |
| No. Outputs (Details) | Four |
| AC input Max (Details) | 264,00 |
| AC input Min (Details) | 90,00 |
| Applications (Details) | Automation of Buildings, Industrial, Instrumentation, Medical, Telecommunications |
| Manufacturer (Details) | MEAN WELL |
| Product type (Details) | Modular chassis |
| Isolation (V) (Details) | 4.000,00 |
| Peak Power (W) (Details) | Six hundred fifty |
| Input connector (Details) | Screw-Type |
| Input frequency (Details) | 50 Hz, 60 Hz |
| Long/Background (Details) | 250.00 |
| Long Description (Details) | Modular chassis, 4 slots and 650W. Version medical and industrial.Format modular in metal box to configure the outputs freely.2 x MOPP.Input range90-264vac47-63Hz.4 Holes(slots) to insert the modules NMS and freely set the output voltages.Maximum power:650W.Efficiency typical:91%.Source certified formedical applications2 x MOPP(primary and secondary) and 1 x MOPP (primary and ground). Suitable for applicationsBF.Voltageoutputprogrammableof the modules by external signal of 1-5vdc.Currentoutputprogrammablebetween 40% and 100% of the modules by external signal of 1-5vdc.Modules paralelizables.Input class I with grounding.Factor corrector, power>0,95to 230vac at full load.Temperature alarms, and correct output DC-OK.Remote on / off of all outputs from the chassis or in each module independently.Auxiliary output on the chassis of 5V 1.5 A, and in each module 5V 10mA.Role of sensing in each module to compensate for the voltage drop in the cables.Low leakage current to earth<400µA. contact Current<100µA.Protection against short circuit, over load, over voltage and temperature.Operating temperature range of caseTcfrom-30up+70ºC.Dimensions (Length x Width x Height):250 x 89 x 41mm.5 years of warranty.Manufacturer: MEAN WELL.The series NMP are sources modular for medical applications type BF (body floating), diagnostic applications, equipment, scanners, instrumentation, telecommunication and automation.Consist of a chassis that allows you to integrate 4 or 6 modules that allow us to choose how very versatile the output voltages. These modules have a wide range of adjustment of the output voltage. If we have a team with different output voltages do not need to use a source to feed each component, so we increase the efficiency and reduce EMC emissions totals, which we will simplify the certification of the computer. It also allows us to grow or expand (if we have a gap-free) can insert more output modules in the future to extend the power or output voltages of our system.The output modules NMP allows you to adjust the voltage and output current by an external signal of 1-5V and we can also set up the tension through a potentiometer. Can be turned on and off remotely each module or all the modules at once from the signal remote on / off of the chassis. The modules are paralelizables and serializable which allows us a greater range of configurations of the outputs. We also have an auxiliary output on the chassis and also in each module to be able to feed any electronics necessary for the computer to handle.The integrated fan is controlled by the internal temperature, in such a way that it rotates at the speed necessary to maintain the equipment properly cooled without generating more noise than necessary.The series NMP is certified, CE, UL, EAC, and with the third edition of the regulations on medical 60601-1.The series NMP solution is most versatile to choose different output voltages. |
| Output connector (Details) | Screw-Type |
| Type of Entry CA (Details) | Single-phase |
| Warranty (Years) (Details) | 5,00 |
| Country of Origin (Details) | Taiwan |
Technical specifications and performance data