| Parameter | Value |
|---|---|
| GTIN | 4046356013130 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2880888 |
| (General) | ≤ 1 kV (at 1 kA (8/20 μs)) |
| Catalog page | Page 143 (C-6-2013) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| EN type (General) | T3 |
| Custom tariff number | 85363030 |
| (Ambient conditions) | EN 61643-1 |
| Type (Ambient conditions) | Attachment plug |
| Color (Ambient conditions) | white |
| Depth (Key Commercial Data) | 106.5 mm |
| Width (Key Commercial Data) | 63 mm |
| Height (Key Commercial Data) | 79 mm |
| Nominal current IN (General) | 16 A (30 °C) |
| Nominal voltage UN (General) | 230 V AC |
| Response time (L-N) (General) | ≤ 25 ns (L-N) |
| Combination wave UOC (General) | 4 kV |
| Nominal frequency fN (General) | 50 Hz |
| Residual current IPE (General) | ≤ 1 µA |
| Response time (L-PE) (General) | ≤ 100 ns (L, N-PE) |
| Degree of protection (Dimensions) | IP20 (child-proof) |
| Mounting type (Ambient conditions) | Plugging into the mains socket |
| Arrester rated voltage UC (General) | 275 V AC (L-N) |
| Max. required back-up fuse (General) | 16 A (gL/C) |
| Weight per Piece (excluding packing) | 191.300 g |
| Housing material (Ambient conditions) | PA |
| Energy absorption symmetrical (General) | 140 J (L-N) |
| Arrester rated voltage UC(L-N) (General) | 275 V AC |
| Degree of pollution (Ambient conditions) | 2 |
| Direction of action (Ambient conditions) | L/N-PE & Signal Line-Shield-Earth Ground |
| Enery absorption, asymmetrical (General) | 220 J (L(N)-PE) |
| Surge protection fault message (General) | optical |
| Total surge current (8/20) µs (General) | 5 kA |
| Arrester rated voltage UC(L-PE) (General) | 360 V AC |
| Arrester rated voltage UC(N-PE) (General) | 360 V AC |
| Connection method (Power supply, general) | Via protective contact plug |
| Overvoltage category (Ambient conditions) | III |
| Voltage protection level Up(L-N) (General) | ≤ 1.2 kV |
| Voltage protection level Up(L-PE) (General) | ≤ 1.5 kV |
| Voltage protection level Up(N-PE) (General) | ≤ 1.5 kV |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 75 °C |
| (Standards (protective circuit, power supply)) | D1 - 1 kA |
| Max. discharge current Imax(8/20) µs (General) | 8 kA (> 100x 1 kA) |
| (Connection (protective circuit, power supply)) | IEC 60884-1 |
| For country-specific use in (Ambient conditions) | S, FIN, N |
| Nominal discharge current In(8/20) µs (General) | 3 kA |
| Total surge current (8/20) µs (Ambient conditions) | 5 kA |
| Connection method IN (Protective circuit, power supply) | Grounding plug |
| Connection method OUT (Protective circuit, power supply) | Grounding socket |
| Flammability rating according to UL 94 (Ambient conditions) | V0/HB |
| (Connection, equipotential bonding, information technology) | EN 50083 - CLASS A |
| Connection method (Protective circuit, information technology) | F connector |
| Frequency range (Standards (protective circuit, power supply)) | 0 Hz ... 2400 MHz |
| Connection method IN (Protective circuit, information technology) | F connector, female |
| Nominal current IN (Standards (protective circuit, power supply)) | 1.5 A (25 °C) |
| Connection method OUT (Protective circuit, information technology) | F connector, female |
| Residual current IPE (Standards (protective circuit, power supply)) | ≤ 1 µA |
| Standards for cearances and creepage distances (Ambient conditions) | EN 60664-1 |
| Standards/regulations (Connection (protective circuit, power supply)) | IEC 61643-1 |
| Arrester rated voltage UC (Standards (protective circuit, power supply)) | 72 V DC |
| Insulation resistance Riso (Standards (protective circuit, power supply)) | ≥ 70 MΩ (core-core) |
| Input attenuation aE, asym. (Standards (protective circuit, power supply)) | 0.3 dB (≤ 2.4 GHz) |
| Capacity asymmetrical (shield) (Standards (protective circuit, power supply)) | typ. 10 pF |
| Pulse reset time (line-shield) (Standards (protective circuit, power supply)) | Cannot be measured |
| Response time tA (line-shield) (Standards (protective circuit, power supply)) | ≤ 100 ns |
| Response time tA (shield-earth) (Standards (protective circuit, power supply)) | ≤ 100 ns |
| Impulse durability (line-shield) (Standards (protective circuit, power supply)) | C2 - 4 kV/2 kA |
| Impulse durability (shield-earth) (Standards (protective circuit, power supply)) | C2 - 10 kV / 5 kA |
| Overload failure mode (line-line) (Standards (protective circuit, power supply)) | Mode 3 |
| Standards/regulations (Connection, equipotential bonding, information technology) | IEC 61643-21 |
| Operating effective current ICat UC (Standards (protective circuit, power supply)) | ≤ 1 µA |
| Residual voltage at In(line-shield) (Standards (protective circuit, power supply)) | ≤ 40 V |
| IEC test classification (Connection, equipotential bonding, information technology) | C2 |
| Residual voltage at In(shield-earth) (Standards (protective circuit, power supply)) | ≤ 50 V |
| Arrester rated voltage UC(Core-Shield) (Standards (protective circuit, power supply)) | 72 V DC |
| Arrester rated voltage UC(Shield-Earth) (Standards (protective circuit, power supply)) | 380 V DC |
| Voltage protection level Up(line-shield) (Standards (protective circuit, power supply)) | ≤ 700 V (C2 - 2 kA) |
| Voltage protection level Up(shield-ground) (Standards (protective circuit, power supply)) | ≤ 1.2 kV (C2 - 5 kA) |
| Alternating current carrying capacity (line-shield) (Standards (protective circuit, power supply)) | 5 A - 1 s |
| Alternating current carrying capacity (shield-earth) (Standards (protective circuit, power supply)) | 10 A - 1 s |
| Nominal discharge current In(8/20) µs (line-shield) (Standards (protective circuit, power supply)) | 2.5 kA |
| Nominal discharge current In(8/20) µs (shield-earth) (Standards (protective circuit, power supply)) | 5 kA |
| Nominal pulse current ian (10/1000) µs, asym. (shield) (Standards (protective circuit, power supply)) | 120 A |
| Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system (Standards (protective circuit, power supply)) | > 2.5 GHz |
Technical specifications and performance data