| Parameter | Value |
|---|---|
| UNSPSC 11 (ETIM) | 39121432 |
| ETIM 3.0 (eCl@ss) | EC001121 |
| ETIM 4.0 (eCl@ss) | EC002643 |
| ETIM 5.0 (eCl@ss) | EC002643 |
| ETIM 6.0 (eCl@ss) | EC002643 |
| (Connection data) | Cable cross section:16 mm²; Torque:2.5 Nm; Form of cable:round, single-strand, class 1(re) |
| UNSPSC 13.2 (ETIM) | 39121432 |
| UNSPSC 6.01 (ETIM) | 30211801 |
| UNSPSC 12.01 (ETIM) | 39121432 |
| UNSPSC 7.0901 (ETIM) | 39121432 |
| GTIN (Your advantages) | 4046356033350 |
| Note (Key Commercial Data) | Tightening torque ≤ 25 mm² is 2.5 Nm, > 25 mm² is 4.5 Nm |
| Orderkey (Your advantages) | 1706600 |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Packing unit (Your advantages) | 25 pc |
| Specification (Connection data) | DIN VDE 0276-603 (VDE 0276-603):2010-03 |
| Screw thread (Key Commercial Data) | M5 |
| Country of origin (Your advantages) | SK (Slovakia) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Custom tariff number (Your advantages) | 85369010 |
| Stripping length (Key Commercial Data) | 18 mm |
| Range of articles (Key Commercial Data) | MKDSP 25/..-F |
| (Information on the aluminum conductor) | CUL |
| Minimum order quantity (Your advantages) | 25 pc |
| Nominal current IN (Key Commercial Data) | 125 A |
| Solder pin surface (Key Commercial Data) | Sn |
| Insulating material (Key Commercial Data) | PA |
| Number of positions (Key Commercial Data) | 6 |
| Conductor cross section AWG max. (General) | 2 |
| Conductor cross section AWG min. (General) | 20 |
| Rated voltage (II/2) (Key Commercial Data) | 1000 V |
| Nominal cross section (Key Commercial Data) | 35 mm² |
| Rated voltage (III/2) (Key Commercial Data) | 1000 V |
| Rated voltage (III/3) (Key Commercial Data) | 1000 V |
| Tightening torque max (Key Commercial Data) | 4.5 Nm |
| Conductor cross section solid max. (General) | 35 mm² |
| Conductor cross section solid min. (General) | 0.5 mm² |
| Tightening torque, min (Key Commercial Data) | 2.5 Nm |
| eCl@ss 4.0 (Environmental Product Compliance) | 27141109 |
| eCl@ss 4.1 (Environmental Product Compliance) | 27141109 |
| eCl@ss 5.0 (Environmental Product Compliance) | 27141190 |
| eCl@ss 5.1 (Environmental Product Compliance) | 27141190 |
| eCl@ss 6.0 (Environmental Product Compliance) | 27261101 |
| eCl@ss 7.0 (Environmental Product Compliance) | 27440401 |
| eCl@ss 8.0 (Environmental Product Compliance) | 27440401 |
| eCl@ss 9.0 (Environmental Product Compliance) | 27440401 |
| Conductor cross section flexible max. (General) | 35 mm² |
| Conductor cross section flexible min. (General) | 0.5 mm² |
| Internal cylindrical gage (Key Commercial Data) | B7 |
| Note on conductor pretreatment (Connection data) | The following measures are required for durable and reliable contacting of the aluminum conductor: the stripped end of the aluminum conductor must be separated from the oxide layer using a blade, and immediately dipped in non-acid and non-alkali Vaseline. The pretreatment must be repeated when connecting the conductors anew. |
| Rated surge voltage (II/2) (Key Commercial Data) | 8 kV |
| Rated surge voltage (III/2) (Key Commercial Data) | 8 kV |
| Rated surge voltage (III/3) (Key Commercial Data) | 8 kV |
| Cross section-torque-form of cable (Connection data) | Cable cross section:35 mm²; Torque:4.5 Nm; Form of cable:round, single-strand, class 1(re) |
| Connection in acc. with standard (Key Commercial Data) | EN-VDE |
| Weight per Piece (excluding packing) (Your advantages) | 127.180 g |
| 2 conductors with same cross section, solid max. (General) | 6 mm² |
| 2 conductors with same cross section, solid min. (General) | 0.5 mm² |
| 2 conductors with same cross section, stranded max. (General) | 6 mm² |
| 2 conductors with same cross section, stranded min. (General) | 0.5 mm² |
| Connection in acc. with standard (Information on the aluminum conductor) | EN-VDE |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (General) | 35 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (General) | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (General) | 35 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (General) | 1 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (General) | 4 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (General) | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (General) | 16 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (General) | 0.5 mm² |
Technical specifications and performance data