| Parameter | Value |
|---|---|
| GTIN | 4046356145312 |
| Orderkey | 1728714 |
| Packing unit | 25 pc |
| Country of origin | SK (Slovakia) |
| Custom tariff number | 85369010 |
| (Ambient conditions) | |
| Minimum order quantity | 25 pc |
| Dry heat (Vibration test) | 168 h/100°C |
| Note (Connection capacity) | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Voltage (Electrical tests) | 1000 V |
| Humid heat (Vibration test) | 48 h/30 °C/92 % |
| Pitch (Key Commercial Data) | 15 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Test result (Vibration test) | Test passed |
| Torque (Electrical parameters) | 2.5 Nm ... 4.5 Nm (⤠25 mm² = 2.5 Nm; 35 mm² = 4.5 Nm) |
| Pitch (Material data - housing) | 15 mm |
| Rated current (Item properties) | 125 A |
| Pin layout (Key Commercial Data) | Linear 2x2 pinning |
| Screw thread (Key Commercial Data) | M5 |
| Test specification (Pull-out test) | IEC 60998-2-1 (in parts) |
| Mounting type (Key Commercial Data) | Wave soldering |
| Test specification (Vibration test) | IEC 60998-2-1:1990-04 |
| (Termination and connection method) | 25 mm² / flexible / > 135 N |
| Weight per Piece (excluding packing) | 108.290 g |
| Dimension a (Material data - housing) | 30 mm |
| Width [ w ] (Material data - housing) | 75 mm |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Contact material (Connection capacity) | Cu alloy |
| Height [ h ] (Material data - housing) | 43.5 mm |
| Length [ l ] (Material data - housing) | 31 mm |
| Number of levels (Key Commercial Data) | 1 |
| Connection method (Key Commercial Data) | Screw connection with tension sleeve |
| Range of articles (Key Commercial Data) | MKDSP 25 |
| Pin dimensions (Material data - housing) | 1.2 x 1.2 mm |
| Solder pin [P] (Material data - housing) | 4.5 mm |
| Stripping length (Electrical parameters) | 18 mm |
| Number of positions (Key Commercial Data) | 3 |
| Delivery state (Dimensions for PCB design) | Open clamping space |
| Hole diameter (Dimensions for the product) | 1.6 mm |
| Drive form screw head (Key Commercial Data) | Philipps recess with slotted Torx (H1L) |
| Insulating material group (Electrical tests) | I |
| Dimensional drawing (Material data - housing) | |
| Insulating material (Material data - contact) | PA |
| Rated surge voltage (II/2) (Electrical tests) | 8 kV |
| Rated surge voltage (III/2) (Item properties) | 8 kV |
| Surface characteristics (Connection capacity) | Tin-plated |
| Type of packaging (Dimensions for PCB design) | packed in cardboard |
| Pieces per package (Dimensions for PCB design) | 25 |
| Rated surge voltage (III/2) (Electrical tests) | 8 kV |
| Rated surge voltage (III/3) (Electrical tests) | 8 kV |
| Brief article description (Key Commercial Data) | PCB terminal block |
| Outer packaging type (Dimensions for PCB design) | Carton |
| Pull-out test (Termination and connection method) | IEC 60998-2-1:1990-04 |
| Rated insulation voltage (II/2) (Electrical tests) | 1000 V |
| Rated insulation voltage (III/2) (Item properties) | 1000 V |
| Insulating material group (Material data - contact) | I |
| Rated insulation voltage (III/2) (Electrical tests) | 1000 V |
| Rated insulation voltage (III/3) (Electrical tests) | 1000 V |
| CTI according to IEC 60112 (Material data - contact) | 600 |
| Conductor cross section solid (Electrical parameters) | 0.5 mm² ... 35 mm² |
| Height (without solder pin) (Material data - housing) | 39 mm |
| Specification (Air clearances and creepage distances) | IEC 60998-2-1 (in parts) |
| Ambient temperature (assembly) (Packaging information) | -5 °C ... 100 °C |
| Denomination packing units (Dimensions for PCB design) | Pcs. |
| Dry heat (Current carrying capacity / derating curves) | 168 h/100°C |
| Rated current (Mechanical tests according to standard) | 125 A |
| Ambient temperature (operation) (Packaging information) | -40 °C |
| Conductor cross section flexible (Electrical parameters) | 0.5 mm² ... 35 mm² |
| Humid heat (Current carrying capacity / derating curves) | 48 h/30 °C/92 % |
| Test result (Current carrying capacity / derating curves) | Test passed |
| Conductor cross section AWG / kcmil (Electrical parameters) | 20 ... 2 |
| Metal surface soldering area (top layer) (Connection capacity) | Tin (5 - 7 µm Sn) |
| Metal surface terminal point (top layer) (Connection capacity) | Tin (5 - 7 µm Sn) |
| Ambient temperature (storage/transport) (Packaging information) | -40 °C ... 70 °C |
| Flammability rating according to UL 94 (Material data - contact) | V0 |
| Test specification (Current carrying capacity / derating curves) | IEC 60998-2-1:1990-04 |
| 2 conductors with same cross section, solid (Electrical parameters) | 0.5 mm² ... 6 mm² |
| Rated surge voltage (III/2) (Mechanical tests according to standard) | 8 kV |
| 2 conductors with same cross section, flexible (Electrical parameters) | 0.5 mm² ... 6 mm² |
| Rated insulation voltage (III/2) (Mechanical tests according to standard) | 1000 V |
| Glow wire flammability index GWFI according to EN 60695-2-12 (Material data - contact) | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 (Material data - contact) | 775 |
| Connection in acc. with standard (Resistance to ageing, humidity and penetration of solids) | EN-VDE |
| Temperature for the ball pressure test according to EN 60695-10-2 (Material data - contact) | 125 °C |
| Conductor cross section / conductor type / tensile force (Termination and connection method) | 0.5 mm² / solid / > 30 N |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical parameters) | 1.5 mm² ... 35 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Electrical parameters) | 1 mm² ... 35 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve (Electrical parameters) | 0.5 mm² ... 4 mm² |
| 2 conductors with same cross section, stranded, with TWIN ferrules with plastic sleeve (Electrical parameters) | 0.5 mm² ... 16 mm² |
| Resistance to ageing, to humidity conditions, to ingress of solid objects and to harmful ingress of water (Current carrying capacity / derating curves) | Test passed IEC 60998-2-1:1990-04 168 h/100°C 48 h/30 °C/92 % |
Technical specifications and performance data
Installation and operation guide