| Parameter | Value |
|---|---|
| 0.14 mm² / flexible / > 10 N | |
| Link | Screw connection with cage |
| Step | 3.5 mm |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| type | PCB terminal block vertical to c.s. |
| Result | Test passed |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Frequency | 10 - 150 - 10 Hz |
| Packaging | Packed in carton |
| Width [w] | 20.95 mm |
| Height [h] | 21.25 mm |
| Length [l] | 15.3 mm |
| Pin Layout | Linear Pinning |
| Shank sizes | 0.6 x 0.8 mm |
| Sweep Speed | 1 octave/min |
| Temperature | 850 °C |
| Color (Case) | Red (3001) |
| No. of poles | 5 |
| Product Type | PCB terminal block |
| Bore diameter | 1.2 mm |
| Mounting type | Wave Soldering |
| Number of rows | 1 |
| Product Family | MKDSO 1.5/.. -R |
| Surface Finish | Galvanic tin plating |
| Contact Material | Cu Alloy |
| Rated Current IN | 8 A |
| Rated voltage UN | 160 V |
| Tightening torque | 0.22 Nm ... 0.25 Nm |
| Test Specification | DIN EN 60998-2-1 (VDE 0613-2-1):2005-03 |
| Degree of pollution | 3 |
| Dimensioned Drawing | |
| Insulation material | PA |
| Number of potentials | 5 |
| Nominal cross-section | 1.5 mm² |
| Number of connections | 5 |
| Sizing voltage (II/2) | 320 V |
| Weld Shank Length [P] | 2.3 mm |
| Sizing voltage (III/2) | 160 V |
| Sizing voltage (III/3) | 160 V |
| Test duration per axle | 2.5 h |
| Duration of application | 5 s |
| Insulation Material Group | The |
| CTI according to IEC 60112 | 600 |
| Conductor cross-section AWG | 28 ... 16 |
| Rated Impulse Voltage (II/2) | 2.5 kV |
| Buffer Gauge a x b / diameter | 2.4 mm x 1.5 mm / - |
| Minimum creepage value (II/2) | 1.6 mm |
| Rated impulse voltage (III/2) | 2.5 kV |
| Rated impulse voltage (III/3) | 2.5 kV |
| Rigid conductor cross-section | 0.14 mm² ... 1.5 mm² |
| Sizing Impulse Voltage (II/2) | 2.5 kV |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Minimum creepage value (III/2) | 0.8 mm |
| Minimum creepage value (III/3) | 2 mm |
| Rated Isolation Voltage (II/2) | 320 V |
| Sizing Impulse Voltage (III/2) | 2.5 kV |
| Sizing impulse voltage (III/3) | 2.5 kV |
| Ambient temperature (operating) | -40 °C ... 105 °C (Depending on current flow curve/derating curve) |
| Rated Isolation Voltage (III/2) | 160 V |
| Flexible conductor cross-section | 0.14 mm² ... 1.5 mm² |
| Heating verification requirement | Temperature rise ≤ 45 K |
| Rated insulation voltage (III/3) | 160 V |
| Length of the section to be stripped | 7 mm |
| Number of Welding Pins per Potential | 1 |
| Ambient temperature (storage/transport) | -40 °C ... 55 °C |
| Combustibility class according to UL 94 | V0 |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| 2 conductors of identical cross-section, rigid | 0.08 mm² ... 0.5 mm² |
| Insulation Resistance Between Contiguous Poles | > 50 GΩ |
| Metal Surface, Connection Point (Surface Layer) | Pond (Sn) |
| 2 conductors of identical flexible cross-section | 0.08 mm² ... 0.75 mm² |
| Minimum creepage value - inhomogeneous range (II/2) | 1.5 mm |
| Minimum creepage value - inhomogeneous range (III/2) | 1.5 mm |
| Minimum clearance value - inhomogeneous range (III/3) | 1.5 mm |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Brinell hardness test temperature according to EN 60695-10-2 | 125 °C |
| GWIT filament ignition temperature according to EN 60695-2-13 | 775 |
| Flammability index of GWFI filament according to EN 60695-2-12 | 850 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 0.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 1.5 mm² |
| Conductor cross-section/conductor type/tensile force nominal value/actual value | 0.14 mm² / rigid / > 10 N |
| 2 conductors of the same flexible cross-section with ferrule without plastic collar | 0.25 mm² ... 0.34 mm² |
| 2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar | 0.5 mm² ... 0.5 mm² |
Technical specifications and performance data
Installation and operation guide