| Parameter | Value |
|---|---|
| GTIN | 4017918975043 |
| Orderkey | 2866336 |
| Catalog page | Page 235 (C-4-2017) |
| Packing unit | 1 pc |
| (Output data) | 3 kV (routine test) |
| Country of origin | CN (China) |
| Custom tariff number | 85044030 |
| (Ambient conditions) | > 100 ms (230 V AC) |
| Derating (Input data) | 60 °C ... 70 °C (2.5%/K) |
| Screw thread (General) | M3 |
| Efficiency (Output data) | > 88 % (for 230 V AC and nominal values) |
| Net weight (Output data) | 0.4 kg |
| Output power (Input data) | 100 W |
| Stripping length (General) | 7 mm |
| Connection method (General) | Pluggable screw connection |
| Depth (Key Commercial Data) | 107 mm |
| Width (Key Commercial Data) | 67.5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 99 mm |
| Residual ripple (Input data) | < 40 mVPP(20 MHz) |
| Protection class (Output data) | II (in closed control cabinet) |
| Input fuse (Ambient conditions) | 3.15 A (slow-blow, internal) |
| Mounting position (Output data) | horizontal DIN rail NS 35, EN 60715 |
| (Connection data for signaling) | NEC Class 2 as per UL 1310 |
| Connection in series (Input data) | yes |
| Degree of protection (Dimensions) | IP20 |
| Degree of protection (Output data) | IP20 |
| Typical response time (Input data) | < 0.4 s |
| Assembly instructions (Output data) | alignable: horizontally 0 mm, vertically 50 mm |
| Connection in parallel (Input data) | Yes, for redundancy and increased capacity |
| Nominal output voltage (Input data) | 24 V DC ±1 % |
| Mains buffering (Ambient conditions) | > 20 ms (120 V AC) |
| Weight per Piece (excluding packing) | 406.000 g |
| Screw thread (Connection data, input) | M3 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 25; |
| Screw thread (Connection data, output) | M3 |
| AC frequency range (Ambient conditions) | 45 Hz ... 65 Hz |
| Operating voltage display (Output data) | Green LED |
| Current consumption (Ambient conditions) | 1.3 A (120 V AC) |
| Input voltage range (Ambient conditions) | 85 V AC ... 264 V AC |
| MTBF (IEC 61709, SN 29500) (Output data) | > 815000 h (40 °C) |
| Nominal output current (IN) (Input data) | 3.8 A (-25 °C ... 60 °C) |
| Inrush surge current (Ambient conditions) | < 15 A (typical) |
| Power loss nominal load max. (Input data) | 12 W |
| Stripping length (Connection data, input) | 7 mm |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 24 |
| Connection method (Connection data, input) | Pluggable screw connection |
| Peak switching voltages idling (Input data) | < 100 mVPP(20 MHz) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| UL approvals (Connection data for signaling) | UL/C-UL listed UL 508 |
| Insulation voltage input/output (Output data) | 3 kV (type test) |
| Noise emission (Connection data for signaling) | EN 55011 (EN 55022) |
| Noise immunity (Connection data for signaling) | EN 61000-6-2:2005 |
| Nominal power consumption (Ambient conditions) | 194 VA |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Nominal input voltage range (Ambient conditions) | 100 V AC ... 240 V AC |
| Rail applications (Connection data for signaling) | EN 50121-4 |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Low Voltage Directive (Connection data for signaling) | Conformance with LV directive 2006/95/EC |
| Setting range of the output voltage (USet) (Input data) | 22.5 V DC ... 26 V DC (> 24 V DC, constant capacity restricted) |
| Choice of suitable circuit breakers (Ambient conditions) | 6 A ... 16 A (Characteristics B, C, D, K) |
| Conductor cross section AWG max. (Connection data, input) | 12 |
| Conductor cross section AWG min. (Connection data, input) | 24 |
| Standard - Safe isolation (Connection data for signaling) | DIN VDE 0100-410 |
| Conductor cross section AWG max. (Connection data, output) | 12 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Conductor cross section solid max. (Connection data, input) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % (at 25 °C, non-condensing) |
| Maximum power dissipation in no-load condition (Input data) | 2.5 W |
| Conductor cross section solid max. (Connection data, output) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| Standard - Electrical safety (Connection data for signaling) | EN 60950-1/VDE 0805 (SELV) |
| Electromagnetic compatibility (Connection data for signaling) | Conformance with EMC Directive 2014/30/EU |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Conductor cross section flexible max. (Connection data, output) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Connection in acc. with standard (Connection data for signaling) | CUL |
| Standard – Safety extra-low voltage (Connection data for signaling) | EN 60950-1 (SELV) |
| Standard – Limitation of mains harmonic currents (Connection data for signaling) | EN 61000-3-2 |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling) | EN 50178/VDE 0160 (PELV) |
Technical specifications and performance data
Installation and operation guide