Key Specifications
GTIN:4046356147989
Orderkey:2866653
Catalog page:Page 237 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356147989
Orderkey2866653
Catalog pagePage 237 (C-4-2017)
Packing unit1 pc
(Output data)3 kV AC (routine test)
Country of originCN (China)
Custom tariff number85044030
(Ambient conditions)typ. 150 ms (230 V AC)
Derating (Input data)60 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 84 % (for 230 V AC and nominal values)
Net weight (Output data)0.25 kg
Output power (Input data)36 W
Connection method (General)Pluggable screw connection
Depth (Key Commercial Data)95 mm
Width (Key Commercial Data)35 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)99 mm
Residual ripple (Input data)< 40 mVPP(with nominal values)
Protection class (Output data)II (in closed control cabinet)
Input fuse (Ambient conditions)3.15 A (slow-blow, internal)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)15 Hz ... 150 Hz, 2.3g, 90 min.
Degree of pollution (Dimensions)2
Feedback resistance (Input data)35 V DC
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
POWER BOOST (IBoost) (Input data)2 A (-25°C ... 40°C)
Degree of protection (Output data)IP20
Typical response time (Input data)< 0.5 s
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)24 V DC ±1 %
ATEX (Connection data for signaling) II 3 G Ex nA nC IIC T4 Gc X
Mains buffering (Ambient conditions)typ. 35 ms (120 V AC)
Weight per Piece (excluding packing)250.000 g
Screw thread (Connection data, input)M3
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Screw thread (Connection data, output)M4
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Current consumption (Ambient conditions)0.75 A (120 V AC)
Input voltage range (Ambient conditions)85 V AC ... 264 V AC
MTBF (IEC 61709, SN 29500) (Output data)> 2789000 h (40 °C)
Nominal output current (IN) (Input data)1.5 A (-25 °C ... 60 °C)
Inrush surge current (Ambient conditions)< 15 A (typical)
Power loss nominal load max. (Input data)6.5 W
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Pluggable screw connection
Insulation voltage input / PE (Output data)4 kV AC (type test)
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
UL approvals (Connection data for signaling)UL/C-UL listed UL 508
Insulation voltage input/output (Output data)4 kV AC (type test)
Nominal power consumption (Ambient conditions)88 VA
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Nominal input voltage range (Ambient conditions)100 V AC ... 240 V AC
Peak switching voltages nominal load (Input data)< 20 mVPP(20 MHz)
Rail applications (Connection data for signaling)EN 50121-4
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Standards/regulations (Connection data for signaling)EN 60079-0
Vibration (operation) (Connection data for signaling)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Choice of suitable circuit breakers (Ambient conditions)6 A ... 16 A (AC: Characteristics B, C, D, K)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)12
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)2.5 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)100 % (condensation permitted)
Maximum power dissipation in no-load condition (Input data)1.5 W
Conductor cross section solid max. (Connection data, output)2.5 mm²
Conductor cross section solid min. (Connection data, output)0.5 mm²
Standard - Electrical safety (Connection data for signaling)EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.5 mm²
Connection in acc. with standard (Connection data for signaling)CUL
Standard – Safety extra-low voltage (Connection data for signaling)EN 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

MINI POWER rail-mounted power supply switched in primary, input: single-phase, output: 24 V DC/1.5 A, for explosion risk area
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top