Service time: Monday to Friday 9:00-18:00
MINI-PS-100-240AC/10-15DC/2 - MINI-PS-100-240AC/10-15DC/2 2938756 PHOENIX CONTACT Power supply unit
In Stock Hot Product

MINI-PS-100-240AC/10-15DC/2

MINI-PS-100-240AC/10-15DC/2 2938756 PHOENIX CONTACT Power supply unit

$0.00USD
3747 in stock
Key Specifications
GTIN:4017918925192
Orderkey:2938756
Catalog page:Page 236 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918925192
Orderkey2938756
Catalog pagePage 236 (C-4-2017)
Packing unit1 pc
(Input data)15 V DC ±1 %
(Output data)3 kV (routine test)
Country of originPL (Poland)
Custom tariff number85044030
(Ambient conditions)> 120 ms (230 V AC)
Derating (Input data)60 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 86 % (for 230 V AC and nominal values)
Net weight (Output data)0.25 kg
Output power (Input data)30 W
Stripping length (General)7 mm
Connection method (General)Pluggable screw connection
Depth (Key Commercial Data)107 mm
Width (Key Commercial Data)45 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)99 mm
Residual ripple (Input data)< 20 mVPP(20 MHz)
Protection class (Output data)II (in closed control cabinet)
Input fuse (Ambient conditions)2 A (slow-blow, internal)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
POWER BOOST (IBoost) (Input data)2.3 A (-25°C ... 40°C permanent )
Degree of protection (Output data)IP20
Typical response time (Input data)< 1 s
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Connection in parallel (Input data)Yes, for assembling redundant systems and increasing efficiency
Nominal output voltage (Input data)12 V DC ±1 %
Mains buffering (Ambient conditions)> 20 ms (120 V AC)
Weight per Piece (excluding packing)250.000 g
Screw thread (Connection data, input)M3
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Screw thread (Connection data, output)M3
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Operating voltage display (Output data)Green LED
Current consumption (Ambient conditions)0.4 A (120 V AC)
Input voltage range (Ambient conditions)85 V AC ... 264 V AC
MTBF (IEC 61709, SN 29500) (Output data)> 507000 h (40 °C)
Nominal output current (IN) (Input data)2 A (-25 °C ... 60 °C)
Inrush surge current (Ambient conditions)< 15 A (typical)
Power loss nominal load max. (Input data)< 7 W
Stripping length (Connection data, input)7 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Pluggable screw connection
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
UL approvals (Connection data for signaling)UL/C-UL listed UL 508
Insulation voltage input/output (Output data)4 kV (type test)
Noise emission (Connection data for signaling)EN 55011 (EN 55022)
Noise immunity (Connection data for signaling)EN 61000-6-2:2005
Nominal power consumption (Ambient conditions)44 VA
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Nominal input voltage range (Ambient conditions)100 V AC ... 240 V AC
Peak switching voltages nominal load (Input data)< 100 mVPP(20 MHz)
Rail applications (Connection data for signaling)EN 50121-4
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Low Voltage Directive (Connection data for signaling)Conformance with LV directive 2006/95/EC
Setting range of the output voltage (USet) (Input data)10 V DC ... 15 V DC (> 12 V DC, constant capacity restricted)
Choice of suitable circuit breakers (Ambient conditions)6 A ... 16 A (Characteristics B, C, D, K)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)12
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)2.5 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 1 W
Conductor cross section solid max. (Connection data, output)2.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Connection in acc. with standard (Connection data for signaling)CUL
Standard – Safety extra-low voltage (Connection data for signaling)EN 60950-1 (SELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

MINI POWER primary switching power supply for rail mounting, input: single-phase, output: 10 V DC ... 15 V DC/2 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top