Key Specifications
GTIN:4046356577731
Orderkey:2320199
Catalog page:Page 257 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356577731
Orderkey2320199
Catalog pagePage 257 (C-4-2017)
Packing unit1 pc
(Input data)60 V DC
Country of originCN (China)
Custom tariff number85044030
Derating (Input data)60 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 95.7 % (For 42 V AC and nominal values)
Net weight (Output data)0.16 kg
(Connection data, output)15 Hz ...150 Hz, 2.3g
Stripping length (General)7 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Pluggable screw connection
Depth (Key Commercial Data)107 mm
Width (Key Commercial Data)22.5 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)99 mm
Residual ripple (Input data)< 3.6 VPP
Protection class (Output data)III
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
Shock (Connection data, output)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Degree of pollution (Dimensions)2
Connection in series (Input data)No
Degree of protection (Dimensions)IP20
Output voltage range (Input data)15 V DC ... 60 V DC
Comments (Connection data, output)Criterion B
Degree of protection (Output data)IP20
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Nominal output voltage (Input data)28 V DC ±1 %
Weight per Piece (excluding packing)160.000 g
Screw thread (Connection data, input)M3
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
UL approvals (Connection data, output)UL/C-UL listed UL 508
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Current consumption (Ambient conditions)6.5 A
Input voltage range (Ambient conditions)10 V AC ... 42 V AC
MTBF (IEC 61709, SN 29500) (Output data)> 18175000 h (40 °C)
Noise emission (Connection data, output)EN 55011 (EN 55022)
Noise immunity (Connection data, output)EN 61000-6-2:2005
Nominal output current (IN) (Input data)3 A (-25 °C ... 60 °C)
Frequency range (Connection data, output)80 MHz ... 3 GHz
Inrush surge current (Ambient conditions)< 45 A (typical)
Power loss nominal load max. (Input data)< 6.9 W
Stripping length (Connection data, input)7 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Pluggable screw connection
Nominal input voltage (Ambient conditions)24 V AC
Contact discharge (Connection data, output)8 kV (Contact discharge)
Rail applications (Connection data, output)EN 50121-4
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Test field strength (Connection data, output)10 V/m
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Low Voltage Directive (Connection data, output)Conformance with LV directive 2006/95/EC
Standards/regulations (Connection data, output)EN 61000-4-4
Vibration (operation) (Connection data, output)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Nominal input voltage range (Ambient conditions)10 V AC ... 42 V AC
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Standard - Electrical safety (Connection data, output)EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data, output)Conformance with EMC Directive 2014/30/EU
Choice of suitable circuit breakers (Ambient conditions)16 A (Characteristic C)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Connection in acc. with standard (Connection data, output)CUL
Conductor cross section solid max. (Connection data, input)2.5 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 0.04 W
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data, output)EN 50178/VDE 0160 (PELV)