Service time: Monday to Friday 9:00-18:00
MINI MCR-TC-UI-NC - MINI MCR-TC-UI-NC 2902851 PHOENIX CONTACT Thermocouple measuring transducer
In Stock Hot Product

MINI MCR-TC-UI-NC

MINI MCR-TC-UI-NC 2902851 PHOENIX CONTACT Thermocouple measuring transducer

$0.00USD
3074 in stock
Key Specifications
GTIN:4046356689229
Orderkey:2902851
(General):Class I, Zone 2, Group IIC
Catalog page:Page 107 (C-7-2015)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356689229
Orderkey2902851
(General)Class I, Zone 2, Group IIC
Catalog pagePage 107 (C-7-2015)
Depth (Note)102.5 mm
Packing unit1 pc
Width (Note)6.2 mm
(Input data)< 20 mVPP(at 500 Ω)
Height (Note)93.1 mm
ATEX (General) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC
Ripple (Input data)< 20 mVPP
Custom tariff number85437090
Conformance (General)CE-compliant
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Color (Connection data)green
Noise emission (General)EN 61000-6-4
UL, USA/Canada (General)UL 508 Listed
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Electrical isolation (General)Basic insulation according to EN 61010
Number of outputs (Input data)1
Power consumption (Output data)≤ 700 mW (at IOUT= 20 mA, 9.6 V DC, load 500 Ω)
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)12 mm
Connection method (Power supply)Screw connection
Max. output current (Input data)24.6 mA
Max. output voltage (Input data)approx. 12.3 V
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Status display (Connection data)LED red
UL, USA/Canada (Connection data)UL 508 Listed
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PBT
Short-circuit current (Input data)< 31.5 mA
Supply voltage range (Output data)9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Voltage output signal (Input data)0 V ... 10 V
Mounting position (Connection data)any
Protective circuit (Connection data)Transient protection
Weight per Piece (excluding packing)118.400 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)Basic insulation according to EN 61010
Max. current consumption (Output data)72 mA
Overvoltage category (Connection data)II
Electromagnetic compatibility (General)Conformance with EMC directive
Cold point error, max. (Connection data)< 3 K
Typical current consumption (Output data)< 27 mA (at 24 V DC)
Rated insulation voltage (Connection data)50 V AC/DC
Typical cold point errors (Connection data)< 2 K
Ambient temperature (operation) (Dimensions)-20 °C ... 65 °C
Load/output load current output (Input data)< 500 Ω (at 20 mA)
Load/output load voltage output (Input data)≥ 10 kΩ
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Configurable/programmable (Ambient conditions)Yes
Certificate of classification (Connection data)DNV GL 14085-15HH
Conductor cross section AWG max. (Power supply)12
Conductor cross section AWG min. (Power supply)26
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)≤ 0.01 %/K
Transmission error thermocouples (Connection data)0.1 % * 600 K / set measuring range; 0.1 % > 600 K (E, J, K, N, T, L, U, M Gost, L Gost)
Test voltage, input/output/supply (Connection data)1.5 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types that can be used (TC) (Ambient conditions)B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Fire protection for rail vehicles (DIN EN 45545-2) R22 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2

Product Description

Configurable temperature converter for thermocouple connection. Configurable via DIP switches or with the extended functionality by software. Screw connection, standard configuration.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top