| Parameter | Value |
|---|---|
| GTIN | 4046356681865 |
| Orderkey | 2902830 |
| (EMC data) | Class I, Zone 2, Group IIC |
| Catalog page | Page 102 (C-7-2015) |
| Depth (Note) | 102.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 6.2 mm |
| Height (Note) | 93.1 mm |
| ATEX (EMC data) | II 3 G Ex nA IIC T4 Gc X |
| Country of origin | DE (Germany) |
| (Connection data) | Class I, Zone 2, Group IIC |
| Comments (EMC data) | Criterion B |
| Ripple (Input data) | < 20 mVPP(at 500 Ω) |
| Custom tariff number | 85437090 |
| (Ambient conditions) | 0.4 mA ... 2 mA |
| Designation (General) | Conducted interferences |
| ATEX (Connection data) | II 3 G Ex nA IIC T4 Gc X |
| Conformance (EMC data) | CE-compliant |
| Designation (EMC data) | Conducted interferences |
| Color (Connection data) | green |
| Noise emission (EMC data) | EN 61000-6-4 |
| UL, USA/Canada (EMC data) | UL 508 Listed |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Conformance (Connection data) | CE-compliant |
| Number of outputs (Input data) | 1 |
| Electrical isolation (EMC data) | Basic insulation according to EN 61010 |
| Power consumption (Output data) | 28 mW (without signal) |
| Standards/regulations (General) | EN 61000-4-6 |
| Stripping length (Power supply) | 8 mm |
| Alignment span (Connection data) | ± 2 % |
| Alignment zero (Connection data) | ± 2 % |
| Connection method (Power supply) | Spring-cage connection |
| Max. output current (Input data) | 35 mA (output limit) |
| Noise emission (Connection data) | EN 61000-6-4 |
| Noise immunity (Connection data) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Standards/regulations (EMC data) | EN 61000-4-6 |
| UL, USA/Canada (Connection data) | UL 508 Listed |
| No. of channels (Connection data) | 1 |
| Current output signal (Input data) | 4 mA ... 20 mA |
| Housing material (Connection data) | PBT |
| Supply voltage range (Output data) | no separate supply voltage necessary |
| Mounting position (Connection data) | any |
| Weight per Piece (excluding packing) | 74.400 g |
| Degree of pollution (Connection data) | 2 |
| Number of inputs (Ambient conditions) | 1 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Configurable/programmable (Input data) | Yes, preconfigured |
| Electrical isolation (Connection data) | Basic insulation according to EN 61010 |
| Overvoltage category (Connection data) | II |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Max. input current (Ambient conditions) | < 50 mA (Dielectric strength up to 30 V) |
| max. input voltage (Ambient conditions) | < 40 V |
| Electromagnetic compatibility (EMC data) | Conformance with EMC directive |
| Limit frequency (3 dB) (Connection data) | approx. 30 Hz |
| Step response (10-90%) (Connection data) | approx. 16 ms |
| Current input signal (Ambient conditions) | 0 mA ... 40 mA |
| Voltage input signal (Ambient conditions) | 0 mV ... 1000 mV |
| Rated insulation voltage (Connection data) | 50 V AC/DC |
| Test voltage input/output (Connection data) | 1.5 kV (50 Hz, 1 min.) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C |
| Load/output load current output (Input data) | < 1000 Ω ((UB- 8 V) / 22 mA) |
| Maximum transmission error (Connection data) | < 0.1 % (of final value) |
| Utilization restriction (Key Commercial Data) | 1 |
| Certificate of classification (Connection data) | DNV GL 14085-15HH |
| Conductor cross section AWG max. (Power supply) | 12 |
| Conductor cross section AWG min. (Power supply) | 24 |
| Electromagnetic compatibility (Connection data) | Conformance with EMC directive |
| Conductor cross section solid max. (Power supply) | 2.5 mm² |
| Conductor cross section solid min. (Power supply) | 0.2 mm² |
| Maximum temperature coefficient (Connection data) | 0.01 %/K |
| Temperature coefficient, typical (Connection data) | 0.005 %/K |
| Input resistance current input (Ambient conditions) | ≤ 50 Ω |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section flexible max. (Power supply) | 2.5 mm² |
| Conductor cross section flexible min. (Power supply) | 0.2 mm² |
| Input resistance of voltage input (Ambient conditions) | approx. 100 kΩ (At ≤ 1 V, otherwise approximately 1 MΩ) |
| Typical deviation from the measuring range final value (General) | 0.5 % |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (EMC data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (EMC data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (EMC data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) | HL 1 - HL 2 |
Technical specifications and performance data
Installation and operation guide